Installation
Installation rules
-
This appliance has been designed to be installed in residential premises.
Please contact your distributor for all other cases.
-
The appliance must be installed in accordance with the the regulations
and current regulatory practices in the country where the appliance
is installed.
-
The appliance must be powered with 220-230 V Single phase 50Hz.
-
In damp rooms such as bathrooms and kitchens, you must install the
connection unit at least 25 cm from the floor.
Keep the appliance away from any air currents that may
interfere with its operation
(e.g.: under Controlled Mechanical
Ventilation, etc.)
.
Volume 1 No electrical appliance
Volume 2
IPX4 electrical appliance
(
Standard EN 60335-2-
43: 2003/A2: 2008
)
≥200 mm
≥250 mm
≥150 mm
≥250
mm
19.0°
Respect the minimum distances
from furniture when positioning the
appliance.
Do not install any shelves above the
appliance. Keep a clearance of 50 cm
in front of the unit.
The unit must be at least 5 mm away
from the wall.
To avoid any danger for very young
children, we recommend installing
this appliance so that the lowest
heating bar is at least 600 mm above
the ground.