PowerTALK 101
29
List all available PowerTALK units
From a command prompt in Windows 95/98/NT, type:
PT –I10.1.1.7
A list will be displayed with the connected PowerTALK units, for this example 10.121.3.85 is the
PowerTALK 101 unit assumed to be connected.
Set a PowerTALK unit name
From a command prompt in Windows 95/98/NT, type:
PT –I10.1.1.7 martian hostname 10.121.3.85 OUTSTN1
where
“martian”
is the default network password,
where “
hostname”
is the item to change command and
where “
OUTSTN1”
is the new unit name.
Change some parameters
From a command prompt in Windows 95/98/NT, type:
PT –I10.1.1.7 martian speed OUTSTN1 2 4800
where
“2” is the port number on
OUTSTN1
Change a port/channel allocation
From a command prompt in Windows 95/98/NT, type:
PT –I10.1.1.7 martian broadcast OUTSTN1 2 34
where
“34” is the new channel number of port number “2” on
OUTSTN1
Accept all changes
From a command prompt in Windows 95/98/NT, type:
PT –I10.1.1.7 martian commit OUTSTN1
to store changes into non-volatile memory