Cochran COMMANDER EMC-20H Owner'S Manual Download Page 7

 

 

4.  To reprogram the displayed menu values, bridge Contacts 1 & 2 with 

wetted fingers.  This will cause the current setting to flash or in the 
case of multi-digit numbers, the least significant digit will flash. The 
clock will toggle between on and off. 

5.  Using a coin or other conductive metal object, bridge Contacts 2 & 3 to 

increment the numeric value.  A confirmation beep will sound with 
each increment. 

6.  Next using wetted finger, bridge Contacts 1 & 2 to select the next digit, 

once selected the digit will flash to identify that it is being programmed.  
Bridge Contacts 2 & 3 till the desired value is displayed. 

7.  Repeat step 5 until all digits have been programmed. 

8.  To save the changes that have been made bridge Contact 1 & 2 with a 

coin or other conductive metal object.  Once the next programming 
option is displayed the changes have been saved. 

All programming sequences use the same routine of using Contacts 1 and 
2 to SELECT the next programming sequence and Contacts 2 and 3 to 
INCREMENT the specified value.  

 

 
PROGRAMMING MENU 

 

The ANALYST

®

 Personal Computer Interface allows the user to enable or 

disable the second gas mix; the following table lists the various 
programming choices with their display identification and figure number 
using two gas mixes.  

Identification  Description 

         

 

          Figure       Page 

CLC

 

 

Clock - if enabled 

 

 

40 

    4 

PdP 

     

PreDive Prediction 

 

 

22 

    7 

InF 

 

Misc. 

Information  

 

 

23 

    7 

dEP 

AL 

Depth Alarm, Max value is 320 feet. 

25 

    7 

Con

 

 

Added Conservatism, Max value is 50%. 26 

    7 

EAn      1

 

Oxygen percentage of Blend, 
Allowed value 21 to 50.   

 

27 

    7 

EAn      2

 

Deco FO2 Oxygen percentage, 
Allowed value 21 to 99.9.    

 

28 

    7 

dEC      b

 

Bottom Time Benchmark for Deco  
FO2  switching, Allowed  
value 10 to 999 minutes

.

    

 

 

29 

    7 

dEC      d

 

Depth Benchmark for Deco FO2 
switching, Max value is 99 feet.   

30 

    7 

TAc 

dL 

TACLITE™ On Time  
Allowed value 00 to 99.   

 

33 

    7 

LOG 

 

Logbook 

 

 

 

34a 

    7

 

 
 
TOUCH PROGRAMMING - PREDIVE PREDICTION: 

 

 

 

PreDive Prediction is accessed via the Touch Contact Programming 
Menu.  This enables the diver to view the PreDive Prediction information at 
the touch of the Contacts.  During the PreDive Prediction Mode, the unit 
will compute and display the maximum safe time and the calculated PO

2

 

value at that depth.  The EMC-16’s PreDive Prediction starts at 30 feet 
and increases in 10 feet increments.  PreDive Predictions will terminate 
when the No-Decompression (NDC) time prediction reaches two minutes 
or a maximum depth of 320 feet is reached. Additional Conservatism, 
Residual Nitrogen, blend #1 oxygen percentage and Barometric Altitude 
can affect PreDive Predictions.  Once the maximum PreDive Prediction 
depth has been reached the unit will return to the Surface Interval. 
 

 

 
 
 
 
 

 

TOUCH PROGRAMMING - INFORMATION DISPLAY: 

 

 

 

 

The InFormation display is accessed via the Programming Mode.  The 

information presented will depend on the configuration of the dive 
computer. The information in the upper right of screen indicates the unit is 
in the Constant FO2 Mode and the number of gas blends the unit is 
enabled for.  The following table lists the identification and the description. 

Identifier 

Description 

F0  

Air only 

F1  

Single Blend Nitrox, 21 to 50% 

F2  

Two Blend Nitrox, 21 to 50% and 21 to 99.9% 

 
Battery voltage is displayed in the lower center of the screen as a two-digit 
number with a decimal point.  The screen will display the current CNS, 
OTU and battery voltage. The current CNS exposure level is displayed on 
the lower left as a two-digit number proceeded by a lower case “c”.  The 
current OTU value is displayed on the lower right again as a two-digit 
number but preceded by a lower case “o”.  Both the CNS and OTU values 
are expressed as percentages. Figure 24a displays a typical InFormation 
screen for a unit that is enabled for two nitrox blends. 

 

TOUCH PROGRAMMING - DEPTH ALARM:

  The Depth Alarm allows the 

diver to select a maximum depth below which the diver does not wish to 
descend before an alarm is issued.  This depth can be set from 0 to 320 
feet in one foot increments. 
 

 

 
TOUCH PROGRAMMING - CONSERVATISM: 

This programming function 

allows the diver to input an added degree of Conservatism into the EMC-
16’s nitrogen algorithm.  Via Touch Programming the Conservatism can be 
set from 0 to 50%.

 

 

 

 
TOUCH PROGRAMMING - BLEND #1: 

The oxygen percentage of Blend #1 can be programmed from 21.0% to 
50.0%.  Once programmed the oxygen percentage will remain at the value 
programmed until changed by the user. 
 

 

5  

Summary of Contents for COMMANDER EMC-20H

Page 1: ...________ Your Name ____________________________ Your Contact __________________________ ______________________________________ ______________________________________ Purchase Date ____________________...

Page 2: ......

Page 3: ...s the EMC 16 first recognizes a turn on command it begins a Diagnostic function where many aspects of the system will be exercised and tested This procedure takes about three seconds and an audible be...

Page 4: ...ING legend and REMAIN TIME digits will flash By immediately ascending to a shallower depth the diver may avoid a required decompression stop Temperature is measured for two purposes One is to compensa...

Page 5: ...his instrument to be used for deliberate Decompression diving POST DIVE INTERVAL During the first ten minutes or up to thirty minutes if the unit is in the Training Mode after a dive the EMC 16 is in...

Page 6: ...bridge Contacts 1 2 to access the CLoCk Time or Alarm setting screen 5 Shorting Contacts 1 2 with a coin will cause the first digit of the minutes to flash 6 Shorting Contacts 2 3 with a coin will in...

Page 7: ...e unit will compute and display the maximum safe time and the calculated PO2 value at that depth The EMC 16 s PreDive Prediction starts at 30 feet and increases in 10 feet increments PreDive Predictio...

Page 8: ...k is accessed via the Touch Contact Programming see page 4 This enables the diver to view dive statistics the EMC 16 has the ability to provide diving data for the most recent 1024 dives The most rece...

Page 9: ...s having errors the display will alternate between S d or S and S t This warning will be issued whether the computer is in the Surface Interval Dive Mode Decompression Mode or Post Dive Interval In th...

Page 10: ...to as the Normal or Bottom Gas Blend and the Decompression Gas Blend Commonly the Bottom Gas Blend is used from initial entry into the water and for most of the time spent during the dive The Normal G...

Page 11: ...sound Ascent Rate for Deco Predictions 20 to 60 This option allows the diver to select the ascent rate to be used in the forecasting of the displayed Total Decompression time The EMC 16 is shipped fro...

Page 12: ...rom a minimum of 10 minutes to a maximum of 30 minutes in one minute increments As shipped from the factory this is set to 10 This option can only be set via the Professional Edition of the Analyst Se...

Page 13: ...Reorient or relocate the receiving antenna of the affected radio or television Increase the separation between the equipment and the affected receiver Connect equipment and the affected receiver to p...

Page 14: ...ithm The EMC 16 allows the diver to input an added degree of conservatism to the nitrogen algorithm from 0 to 50 percent in one percent increments This can be done via the Touch Contact Programming Mo...

Page 15: ...ttery power even though the unit may be on a dive and can not be activated until fresh batteries are installed While there should be sufficient battery power to normally complete a dive it is not reco...

Page 16: ...11 Dive Mode Alternate Screen FO2 Mode 2 12 Ascent Bar Graph 2 14 PreDive Prediction FO2 Mode 5 15 PO2 Warning Display FO2 Mode 7 16aDeco Mode Primary Screen FO2 Mode Total Time 3 16cDeco Mode Primar...

Page 17: ......

Page 18: ...www divecochran com Cochran EMC 16 Owner s Manual English Imperial Ver EMC16FO2 3 00 1758 Firman Drive Richardson Texas 75081 USA Phone 972 644 6284 Fax 972 644 6286 www divecochran com...

Reviews: