Page 1: ...4 Stroke Engine INVERTER GENERATOR USER MANUAL Model IG32ESI...

Page 2: ......

Page 3: ...the right of modification of product and revision of the manual without any notice Take this manual as a part of the generator If the generator is resold it is required to take the manual along with t...

Page 4: ......

Page 5: ...CONTENT 21 21 23 24 25 27 29 30 31 32 04 06 08 08 09 10 10 11 12 13 15 16 18 19 19 20 07 32 34 RESET Hour meter 09 Stop the engine 33...

Page 6: ...r distance with constructions and other To ensure personal and property safety please carefully read the following information 04 WARNING electrical appliances at least Place the generator on the leve...

Page 7: ...05 SAFETY LABEL...

Page 8: ...06 2 SAFETY LABEL LOCATIONS...

Page 9: ...07 MUFFLER FUEL CAP AIR CLEANER MAINTENANCE COVER HANDLE WHEEL OIL MAINTENANCE COVER CONTROL PANEL STARTER GRIP BATTERY MAINTENANCE COVER...

Page 10: ...08 1 2 3 4 5 6 7 8 9 Hour meter DC Terminal DC Protector Indicator Lights ECON SW Fuel Switch Engine Switch AC Receptacle Ground Terminal 1 2 3 4 5 6 7 9 8...

Page 11: ...on to display the voltage frequency of output the engine speed and cumulative working time Press the DISP button the back light of hour meter will be on and it will be off without operating the button...

Page 12: ...10 Oil Capacity 0 6L...

Page 13: ...e Number of 91 or higher Pump Octane Number of 86 or higher Never use stale or contaminated Petrol or an oil Petrol mixture Avoid getting dirt or water into the fuel tank Do not use a mixture Petrol c...

Page 14: ...thout the air cleaner element the engine will be damaged without the air filter being fitted 4 3 Check Air Cleaner Check the air cleaner element to be sure it is clean and in good condition a Loosen t...

Page 15: ...uld firstly be opened for ten or twenty seconds in order that e enough fuel enters into carburetor 5 STARTING THE ENGINE For some models the generator provides three means to starting the engine recoi...

Page 16: ...3 Choose one of the starting modes to start the engine STARTER GRIP a Manual starting NOTE Return the starter grip slowly by hand Do not make the starter grip spring back quickly b Local electrical st...

Page 17: ...y If the oil alert indicator light red is on during the generator running add oil Carburetor Modification for High Altitude Operation At high altitude the standard carburetor air fuel mixture will be...

Page 18: ...altitude operation the air fuel mixture will be too lean for low altitude use Operation at low altitude may cause the engine to overheat and result in serious engine damage The carburetor needs retur...

Page 19: ...sed while the AC power is in use If both are used at the same time be sure not to exceed the total power for AC and AC 2 6kVA DC 5A Most of motor appliances require more than their rated wattage when...

Page 20: ...e battery away from spark fire Charge the battery in a ventilated condition Battery electrolyte contains sulfuric acid that will cause severe burn of skin and eyes Therefore it is necessary to wear th...

Page 21: ...onfirm all electrical appliances are switched off and connect the appliance plugs to the generator receptacle NOTE To obtain the best working and longest working life of the generator a new generator...

Page 22: ...indicator light red is off and the output indicator light green is on reconnect the electrical appliances Otherwise stop the engine and check the generator OVERLOAD INDICATOR LIGHT RED OUTPUT INDICATO...

Page 23: ...he connected electrical appliances and remove their plugs ON OFF 7 3 Turn the fuel switch to the OFF position 7 2 Turn the engine switch to the STOP position or press the STOP button of the controller...

Page 24: ...Every 2 years or 300 hrs Spark plug Check adjust 1 Fuel tank filter After every 300 hrs 2 Every year 2 Fuel line Every 2 years Replace if necessary 2 Clean Check NOTE 1 Service more frequently when us...

Page 25: ...change wash your hands with soap 8 1 3 Place oil collection pan under oil drain plug 8 1 4 Remove the oil drain plug and drain oil into the oil collection pan completely 8 1 5 Reinstall the oil drain...

Page 26: ...and maintain the air cleaner regularly especially in the extremely dusty areas WARNING Do not use Petrol or low ignition point solvents for cleaning They are flammable and explosive under certain con...

Page 27: ...n engine oil and squeeze out the redundant oil ELEMENT 8 2 5 Reinstall the air cleaner element and cover 8 2 6 Reinstall the maintenance cover and tighten the screws 8 3 Spark Plug Service Recommendat...

Page 28: ...e spark plug carefully by hand to avoid cross threading A new spark plug should be tightened 1 2 turn with a spanner A used Spark plug should be tightened 1 8 to 1 4 turn with spanner NOTE The spark p...

Page 29: ...rester If the spark arrester is worn replace it 8 4 4 Reinstall the spark arrester and muffler guard 8 5 Replace battery and fuse For some models fitted with electrical starting system and starting ba...

Page 30: ...ttery from battery tray and replace a new one 8 5 5 Reconnect red cable to battery positive terminal and reconnect black cable to battery negative terminal NOTE When the engine is running the battery...

Page 31: ...used under a good ventilated condition Avoid exposing directly in the sunshine Avoid leaving in a vehicle during high temperatures The high temperature inside the vehicle could cause fuel to vapourise...

Page 32: ...stall the spark plug cap 9 3 Change new oil while engine is still warm from operation 9 4 Remove the spark plug and pour a tablespoon of clean engine oil 10 20ml into the cylinder Revolve the engine s...

Page 33: ...gine DC receptacle without any electricity Is the output indicator light ON Contact with an authorized Cobra dealer Is the overload indicator light ON Check the electrical appliance for any fault NO Y...

Page 34: ...oise LpA Dimensions L W H Net Weight WorkingAmbientTemperature OTHER SPECIFICATIONS Noise level is measured when the ECON SW is turned to ON L shows the guaranteed sound power wA tested by 2000 14 EC...

Page 35: ...ing Ignition Module AC Receptacle Hourmeter INVERTER Main Winding Aux Winding 1 Aux Winding 2 Stepper Motor Ignition Oil sensor ECON SW Engine Switch Ground Terminal DC Connector Battery 12V 7Ah Actua...

Page 36: ...1 0 69 0 66 0 64 0 62 0 60 0 58 0 56 0 54 0 52 0 50 0 48 0 46 0 500 1000 2000 3000 4000 Ambient temperature Factor of environment correction NOTE Relative humidity 60 correction factorC 0 01 Relative...

Page 37: ...sion and exposure levels this cannot be used reliably to determine whether or not further precautions are required Factors that influence the actual level of exposure of work force include the charact...

Page 38: ...ealer who is professionally trained to complete service work as necessary The Cobra dealer list is available at cobragarden co uk or contact 0115 986 2161 for assistance When contacting your dealer pl...

Page 39: ...ine Displacement 208 cm3 Rated Output Power 2 6 kVA Max 2 8 kVA Measured sound power level 68 dB A Guaranteed sound power level 96 dB A Notified Body for EC Directive 2000 14 EC 0499 T V Rheinland LGA...

Page 40: ...Cobra Garden Machinery Henton and Chattell Ltd London Road Nottingham NG2 3HW UK...