background image

CPP 7500

User Manual

Portable Power - Anytime, Anywhere!

Thank for purchasing the Cobra CPP 7500 JumPack

 jump 

starter portable PowerPack. Before using this product, please 

read these instructions carefully to learn about the features 

and capabilities of the JumPack and how you can get the 

best out of it.

Note: 

Please charge your CPP 7500 JumPack completely 

prior to using it for the first time.

©2014 Cobra Electronics Corp.  Part No. 480-936-P  Printed in China   Version B

Charge the JumPack fully prior to use.
WARNING:

 Keep the unit clear of fire and water. 

WARNING: Shock Hazard.

 Keep away from children. Do not 

insert foreign objects into the jumper cables port/jack, the USB 

output port, or the DC input jack. Do not expose this product to 

water, rain, snow, condensation, or spray. Do not open the 

JumPack to replace the internal battery. No user replaceable 

parts are inside the JumPack. 

WARNING: Explosion Hazard.

 Do not use this product where 

there are flammable fumes or gases, such as in the bilge of a 

gasoline-powered boat, or near propane tanks. Do not use this 

product in an enclosure containing automotive-type lead-acid 

batteries. 

The jump start cable clamps must be connected positive to 

positive (red clip to battery  (+)) and negative to negative (black 

clip to battery (-)).  A reverse polarity connection (positive to 

negative) may cause damage to the JumPack and/or create a 

sparking/explosion hazard.

WARNING: Fire Hazard

Do not crush or puncture the JumPack. Never allow the jump start 

cables’ red and black clamps’ metal contacts to touch each other or 

another common metal conductor.  This could cause damage to the 

unit and/or create a  fire hazard. Always disconnect the jump start 

cables from the JumPack after each use and store separately. The 

jump start feature is designed for short term operation only. 

Turn the ignition key for 

no more than

 

3 seconds

 at a time.  

Operating the jump start feature for more than 

3 seconds

 may 

cause damage to the unit.  Allow the JumPack to cool down for at 

least 

1 minute

 after each jump start attempt.

IMPORTANT SAFETY INSTRUCTIONS

Caution: Operating temperature

Do not expose the JumPack to temperatures over +113° F (+45° C) or 

under -14° F (-10° C).  Using the JumPack at high or low temperatures 

may reduce the internal battery capacity and shorten the battery life.

Note: 

 In extreme cold weather conditions, please bring the JumPack 

indoors for best results.

Precautions when working with batteries
WARNING: Explosion and fire hazard

1.

  Follow all instructions published by the battery manufacturer and the 

manufacturer of the equipment in which the battery is installed.

2.

  Make sure the area around the battery is well-ventilated.

3.

  Never smoke or allow a spark or flame in the vicinity of the engine 

or batteries.

4.

  Be careful not to drop a metal object on the battery or allow a 

metal tool to simultaneously touch the positive and negative cable 

ends or battery terminals.

5.

  Remove personal metal items such as rings, bracelets, necklaces, 

and watches when working with batteries. Batteries produce a 

short-circuit current high enough to weld a ring or other similar 

objects to metal, causing a severe burn.

6

.  If you need to remove a battery, always remove the negative 

terminal from the battery first. Make sure all accessories are

off so you don’t cause an arc.

7.

  Someone should be within range of your voice, or close enough to 

come to your aid when you work near batteries.

8.

  Have plenty of fresh water, soap and a supply of baking soda on 

hand in the area of the batteries in case of contact with battery acid. 

Baking soda neutralizes lead acid battery electrolyte.

9.

  The JumPack is supplied with a rechargeable Li-Cobalt battery. 

This battery is self-contained and not consumer replaceable. Battery 

must be disposed of properly when it no longer holds a charge. Proper 
charging practices will increase the life of the batteries.For information 
on battery recycling call toll free 800-822-8837. 

                                       

                                                           

Product:

Jumper cable with clamps

Battery Status Indicator LEDs 

Jump Starter Cable Input

12V DC Charge Input

USB 5V/2.1 Amp Output

LED Flashlight/Strobe 

Light/ S.O.S Light

Power/Flashlight/Battery 

Capacity Button 

Home adaptor      Car adaptor

Recharging the JumPack:

The CPP 7500 JumPack can be recharged with the supplied 120V AC 

wall charger connected to an AC home outlet or with the supplied 13.8V 

DC vehicle charger.
When the CPP 7500 is charging; the LEDs will show the current battery 

life. The last LED that is lit will blink to show that the JumPack is charging. 

When the JumPack is fully charged the LEDs will turn off automatically. 
For best battery performance the JumPack should be fully recharged 

every 3 months.

Operation:

Check Battery Capacity:

To check the battery capacity of the JumPack press the 

Power/Flashlight button on the top of the unit with no device 

connected. The blue LEDs will show the remaining battery capacity:

1

 LED on: 10%-40% charge

2

 LEDs on: 40%-65% charge

3

 LEDs on: 65%-85% charge

4

 LEDs on: 85%-100% charge

Note:

 When charging a device the number of lit LEDs may 

decrease while the JumPack is in use. The battery capacity 

indicator cannot accurately measure the capacity during rapid 

charging. To confirm the real battery capacity, disconnect the 

device being charged and press the power/flashlight/capacity button.

Battery Status Indicator LEDs 

.1.

.2.

.3.

.4.

CPP7500_MANL.indd   1

2/12/14   10:59 AM

Reviews: