Introduction

WARNING Power inverters contain components  

that can produce arcs or sparks. To prevent fire  

or explosion, do not install the inverter in areas or 

compartments containing batteries or flammable 

materials or in locations that require ignition-

protected equipment.
WARNING To reduce the risk of fire, do not cover  

or obstruct the ventilation openings. Do not 

install inverter in zero-clearance compartment.

Proposition 65: Warning: Wash Hands After 

Handling Power Cord

The power cord on this product contains lead, a chemical 

known in the state of California to cause birth defects or 

other reproductive harm.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries can be 

damaged if connected to the Cobra 800 watt inverter. Two 

particular types of equipment are prone to this problem: 

1.  Small battery-operated 

appliances such as flashlights, 

razors, and night lights that  

can be plugged directly into  

an AC receptacle to recharge.

2.  Certain battery chargers for 

battery packs used in hand  

power tools. These chargers 

have a WARNING label stating 

that dangerous voltages are 

present at the battery terminals.

This problem does not occur with the vast majority of 

battery operated equipment. Most use a separate charger 

or transformer that is plugged into the AC receptacle 

and produces a low voltage output. If the label on the AC 

adapter or charger states that it produces a low voltage  

AC or DC output (less than 30 volts), the inverter will  

have no problem powering the adapter safely.

Output Waveform

Some very sensitive electronic equipment may not operate 

satisfactory on “square wave” or “modified sine wave.”  

The output waveform is referred to as “square wave” or 

“modified sine wave.” It is a stepped waveform designed  

to have characteristics similar to the sine wave shape of 

utility power. A waveform of this nature is suitable for most 

AC loads (including linear and switching power suppliers 

used in electronic equipment, transformers and motors).

Quick Evaluation Before Installation 

This section provides you with basic information about the 

inverter and how to check its performance before installation.

Be Sure to Have on Hand:

£

  A 12 volt DC power source (such as a vehicle battery).

 The power source must provide 

between 11 and 15 volts DC and  

be able to supply enough current to 

run the test load. As a rough guide, 

divide the wattage of the test load by 

10 to get the current (in amperes) 

the power source must deliver.

£

    The provided two foot direct-to-battery 12 gauge cable. 

Only use the cable provided with 

your inverter.

£

  A test load that can be plugged into the AC receptacle on 

the inverter for short term testing at a low power level.

Quick Evaluation  

Before Installation

Intro

Operation

Customer

Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Introduction

Nothing Comes Close to a Cobra

®

Plug In Directly

Dangerous 

Voltages

Power Supply

Cable

Test Load

CPI890_MANL.indd   2-3

11/13/14   3:44 PM

Summary of Contents for CPI890

Page 1: ...se refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated He...

Page 2: ...er is out of warranty a letter will automatically be sent informing you of the repair charge or replacement charge If you have any questions please call 773 889 3087 for assistance Maintenance and Pro...

Page 3: ...paid to the CAUTION and WARNING statements in the manual CAUTION Statements specify conditions which could cause damage to the unit or other equipment WARNING Statements identify conditions that could...

Page 4: ...lugged into the AC receptacle and produces a low voltage output If the label on the AC adapter or charger states that it produces a low voltage AC or DC output less than 30 volts the inverter will hav...

Page 5: ...the same compartment to minimize the length of cable required to connect the inverter to the battery It is better and cheaper to run longer AC wires than longer DC wires cables CAUTION To avoid fire...

Page 6: ...Turn the On Off Switch on the inverter to the off position If the power source is a DC power supply switch it off as well 2 Connect cable to the Power Input Terminals on right side panel of the invert...

Page 7: ...The inverter will be damaged if its output is connected to AC voltage from another source Damage can even occur if the inverter is switched off CAUTION Do not connect the inverter to an AC branch cir...

Page 8: ...in Icons Secondary Icons Caution Warning Installation Nothing Comes Close to a Cobra Power Consumption For each piece of equipment you will be operating from the inverter you must determine the batter...

Page 9: ...ty Notes Notice Main Icons Secondary Icons Caution Warning Installation Operation Operating Limits Power Output The inverter can deliver 800 watts for about 60 minutes The inverter must cool for 15 mi...

Page 10: ...t should be above 12V To extend the life of the fan it will stop when there is no load The speed of the fan increases as the load increases The unit is completely insulated in input and output for add...

Page 11: ...maged by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs 3 If the serial number has been altered defaced or removed 4 If the owner of th...

Reviews: