5
OPERATING LIMITS
INPUT VOLTAGE/AUTO SHUTDOWN
Power Output
AC Output:
Your CPI190 will deliver
130 watts continuously.
(
NOTE:
the wattage rating
applies to resistive loads.)
USB Output:
5 Volt continuous output.
Input Voltage
Your CPI190 will operate from
input voltage ranging from
10.4 to 14.4 volts. Optimum
performance occurs when the
voltage is between 12 and
14 volts.
The inverter will automatically
shut down if the input voltage
drops below 10.0 ± 0.3 volts.
This protects the battery
from being over-discharged.
The inverter will restart when
the input voltage exceeds
12.0 ± 0.3 volts.
The inverter will also shut
down if the input voltage
increases to 15.5 ± 0.5 volts.
This helps protect the unit
from damage due to excessive
input voltage. Although the
inverter is protected in this
way, it may still be damaged
should the input voltage
exceed 16 volts.
Automatic Shutdown
The unit will automatically
go into thermal shutdown if
it becomes overheated due to
excessive input voltage, poor
circulation or high ambient
temperature.
6
Power/Fault Indicator
CPI190_MANL.indd 7