background image

5

Nothing comes close to a Cobra

®

4

English

Installation
Requirements

Cobra 800 Watt Output Waveform

Some very sensitive electronic equipment may not operate
satisfactory on “square wave” or “modified sine wave.”
The output waveform is referred to as “square wave” or
“modified sine wave.” It is a stepped waveform designed
to have characteristics similar to the sine wave shape of
utility power. A waveform of this nature is suitable for most
AC loads (including linear and switching power suppliers
used in electronic equipment, transformers and motors).

Quick Evaluation Before Installation

This section provides you with basic information about the
inverter and how to check its performance before installation.

Be Sure to Have on Hand:

A 12 volt DC power source (such as a vehicle battery).

The power source must provide
between 11 and 15 volts DC and
be able to supply enough current to
run the test load. As a rough guide,
divide the wattage of the test load by
10 to get the current (in amperes)
the power source must deliver.

The provided two foot direct-to-battery 12 gauge cable.

Only use the cable provided with
your inverter.

A test load that can be plugged into the AC receptacle on
the inverter for short term testing at a low power level.

To check your inverter’s performance before installation:

1. Turn the inverter off (see page 11

for details). If the power source
is a DC power supply, switch it
off as well.

2. Connect cables to power input

terminals (see page 7 for details).

3. Connect cables to power source

(see page 7 for details).

4. Check to make sure all

connections are secure.

5. Turn the inverter on. If the

power source is a DC power
supply, switch it on first.

6. Plug in the test load.

The inverter should supply
power to the load. If the inverter
is not working properly, refer to
the troubleshooting guide on
page 14 or power and protection
indicators section on page 12.

Installation

Quick Evaluation
Before Installation

Introduction

On/Off Switch to Off

Connect Terminals

Connect Power Source

On/Off Switch to On

Connect Test Load

All manuals and user guides at all-guides.com

Summary of Contents for CPI 850

Page 1: ...the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m CT Monday through Friday except holida...

Page 2: ...anks to You A1 Customer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 3 Installation Installation Requirements 5 Mounting 6 Connecting Cables 7...

Page 3: ...equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and bat...

Page 4: ...aged if connected to the Cobra 800 watt inverter Two particular types of equipment are prone to this problem 1 Small battery operated appliances such as flashlights razors and night lights that can be...

Page 5: ...he test load by 10 to get the current in amperes the power source must deliver The provided two foot direct to battery 12 gauge cable Only use the cable provided with your inverter A test load that ca...

Page 6: ...es than longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter m...

Page 7: ...r the maximum amount of energy to the load Only use the cables provided with your power inverter To connect the cables between the inverter and the battery 1 Turn the On Off Switch on the inverter to...

Page 8: ...generator or utility power to the AC wiring at the same time The inverter will be damaged if its output is connected to AC voltage from another source Damage can even occur if the inverter is switched...

Page 9: ...from the inverter you must determine the battery s reserve capacity how long the battery can deliver a specific amount of current in automotive batteries usually 25 amperes or ampere hour capacity a...

Page 10: ...e speed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Problem Symptom Low output voltage No output voltage No output voltage after pr...

Page 11: ...o any product damaged by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs 3 If the serial number has been altered defaced or removed 4 If...

Reviews: