Cobra CPI 475 Operating Instructions Manual Download Page 9

13

12

Power and Protection Indicators

The power and protection indicators include a green 
light, a red light and an alarm.

Green Light

Power on – The green light should remain on steady.

Red Light and/or Alarm

Current overload – The red light will blink continuously,
then the inverter will shutdown. The inverter will continue
to check for appropriate current levels while trying to
restart the load.

DC input voltage overload – The red light will turn on and
the inverter will shutdown. The inverter will continue to
check for appropriate voltage levels while trying to restart
the load.

DC input voltage shortage – As a warning that the voltage
is getting low, the internal alarm will sound. When the
voltage is too low, the inverter will shutdown and the red
light will turn on. The inverter will continue to check for
appropriate voltage levels while trying to restart the load.

Temperature overload – The red light will blink, then the
inverter will shutdown. The inverter will continue to check
for appropriate temperature levels while trying to restart
the load.

NOTE A momentary sound of the internal alarm
and/or flash of the red light is normal at start up.

Power and Protection

Indicators

Operation

Operating Limits

Operation

Operating Limits

Power Output

The inverter can deliver 400 watts for about 60 minutes.
The inverter must cool for 15 minutes before it can
resume operation at 400 watts. Note: The wattage 
rating applies to resistive loads.

The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps, 
and other motor-operated equipment require very high 
surge currents to start. The inverter may not be able 
to start some of these motors even though their rated 
current draw is within the inverter’s limits. The inverter 
will normally start single phase induction motors rated 
at one-half HP or less.

Input Voltage

The inverter will operate from input voltage ranging 
from 10 volts to 15 volts. Optimum performance will 
occur when the voltage is between 12 volts and 14 volts.
If the voltage drops below 10.5V+/- 0.3V, an audible low
battery warning will sound. The inverter will shut down if
the input voltage drops below 9.5V+/-0.3V. This protects
the battery from being over-discharged. It will restart when
the input voltage exceeds 12V+/-0.3V.

The inverter will also shut down if the input voltage
exceeds 15.75V+/-0.75V. This protects the inverter 
against excessive input voltage. Although the inverter 
has protection against over-voltage, it may still be
damaged if the input voltage were to exceed 16 volts.

Nothing 

Comes Close to a Cobra

®

10272-CPI475_PH2.qxd  7/9/07  11:30 AM  Page 12

Summary of Contents for CPI 475

Page 1: ...ervices For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m CT Monday through Friday except holidays 773 889 3087 phone Questions English and Spanish Faxes can be received at 773 622 2269 fax Technical Assistance English only www cobra com on line Frequently Asked Questio...

Page 2: ...d by way of a traceable carrier such as United Parcel Service UPS or Priority Mail to avoid loss in transit to Cobra Factory Service Cobra Electronics Corporation 6500 West Cortland Street Chicago Illinois 60707 USA 6 If the power inverter is in warranty upon receipt of your power inverter it will either be repaired or exchanged depending on the model Please allow approximately three to four weeks...

Page 3: ... identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are present 2 Do not operate the inverter if it has been dropped or damaged in any way 3 Do not open the inverter it contains no user serviceable parts Attempting to service unit could cause electrical shock NOTE Inter...

Page 4: ...ly Plug In Directly Dangerous Voltages 3 2 Important Safety Information Introduction Cobra 400 Watt Output Waveform Some very sensitive electronic equipment may not operate satisfactory on square wave or modified sine wave The output waveform is referred to as square wave or modified sine wave It is a stepped waveform designed to have characteristics similar to the sine wave shape of utility power...

Page 5: ...llation Requirements The inverter must be installed in an area that meets all of the following requirements A Dry Do not place in an area where water can drip or splash on the inverter B Cool Ambient air temperature should be between 30 F and 105 F 0 C and 40 C The cooler the better C Ventilate Allow at least one inch three cm of clearance around the inverter for proper airflow Make sure that vent...

Page 6: ...ion Mounting Brackets Mounting Hardware 2 Connect cable to the Power Input Terminals on right side panel of the inverter The red terminal is positive and the black terminal is negative Insert the ends of the cables onto the terminals and tighten the screws to clamp the cables safely 3 Connect cable to your vehicle s cigarette lighter socket NOTE If the inverter is to be used at levels above 150 wa...

Page 7: ...ct the inverter to an AC branch circuit that has high power consumption loads It will not operate electric heaters air conditioners stoves and other electrical appliances that consume more than 400 watts CAUTION Loose connectors result in excessive voltage drop and may cause over heated wires and melted insulation CAUTION Reverse polarity connections positive to negative will blow external fuse in...

Page 8: ...ill be consumed 11 10 Turning Your Inverter On or Off Be sure to have your power inverter properly installed before attempting to turn the unit on see installation page 5 To turn the power inverter on 1 If a DC power supply is being used as the power source switch it on 2 On the left side panel switch the On Off Switch to on The inverter is now ready to deliver AC power to your loads If several lo...

Page 9: ...peration Operating Limits Power Output The inverter can deliver 400 watts for about 60 minutes The inverter must cool for 15 minutes before it can resume operation at 400 watts Note The wattage rating applies to resistive loads The inverter will operate most AC loads within its power rating Some induction motors used in freezers pumps and other motor operated equipment require very high surge curr...

Page 10: ... when there is no load The speed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Problem Symptom Low output voltage No output voltage No output voltage after prolonged use No output voltage Protect indicator lighted No output voltage No power to inverter Low battery alarm on all the time Possible Causes Overload Low input voltage The...

Page 11: ...does not apply 1 To any product damaged by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs 3 If the serial number has been altered defaced or removed 4 If the owner of the product resides outside the U S A All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the...

Reviews: