Turning Your Inverter On or Off

Be sure to have your power inverter properly installed before attempting to 
turn the unit On (see “Installation” page 6).

To Turn the Power Inverter On:

1. If a DC power supply is being used as the power source, switch it On. 

2. On the left side panel, switch the 

On/Off Switch

to On.

The inverter is now ready to deliver AC power to your loads. If several loads 
are to be operated by the inverter, turn them On separately, after the inverter 
has been turned On. This will ensure that the inverter does not have to deliver 
the starting currents required for all the loads at once.

To Turn the Power Inverter Off:

1. On the left side panel, switch the 

On/Off Switch

to Off.

NOTE

The 

On/Off Switch

turns the control circuit in the inverter On and Off. 

It 

does not

disconnect power from the inverter.

When the switch is in the Off position, the inverter draws no current 
from battery. When it’s in the On position, but no power is being supplied 
to the load, the inverter draws less than 500 milliamperes from the battery. 
This is low current draw. It would take more than a week to discharge a 
100 ampere-hour battery at this rate depending on the age of the battery. 

12 English

Ground Wiring

There is a screw on the rear panel for 

Chassis Ground

. This is to connect the chassis 

of the inverter to ground.

The 

Chassis Ground Screw

must be connected to a grounding point, which will vary

depending on where the unit is installed. Use a #8 AWG copper wire (preferably with
green/yellow insulation) to connect the chassis ground screw to the grounding point.

In a Vehicle

:  

Connect the 

Chassis Ground

to the chassis of the vehicle. 

In a Boat:

Connect to the 

Boat Grounding System

In a Fixed Location:

Connect the 

Chassis Ground Screw

to earth ground by connecting 

to a ground rod (a metal rod pounded into the earth) or other proper 
service entrance ground.

Installation

Ground Wiring

Chassis Ground

Power On or Off

Operation

On/Off Switch to On

On/Off Switch to Off

Summary of Contents for CPI 400 M

Page 1: ...e Should you encounter any problems with this product or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electron...

Page 2: ...g Guide 17 Specifications 18 Warranty Warranty 19 Customer Assistance Maintenance 20 Product Service 20 Accessories and Order Form 22 Controls Indicators and Product Features Introduction Table of Con...

Page 3: ...atements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are presen...

Page 4: ...attery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of bat...

Page 5: ...s please connect the inverter directly to the battery A test load that can be plugged into the AC receptacle on the inverter for short term testing at a low power level Quick Evaluation Before Install...

Page 6: ...clearance compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damag...

Page 7: ...e the inverter has a low voltage high current input low resistance wiring is essential between the battery and inverter This is so it can deliver the maximum amount of energy to the load Only use the...

Page 8: ...at each piece of equipment will be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the tot...

Page 9: ...r draws no current from battery When it s in the On position but no power is being supplied to the load the inverter draws less than 500 milliamperes from the battery This is low current draw It would...

Page 10: ...emperature Overload The red light will turn On momentarily then the inverter will shutdown The inverter must be turned Off then back On to reset NOTE A momentary sound of the internal alarm and or fla...

Page 11: ...m being over discharged The inverter must be turned Off then back On to reset The inverter will also shut down if the input voltage exceeds 15 75V 0 75V This protects the inverter against excessive in...

Page 12: ...ding warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty Cobra shall not be liable for any incidental consequential or other damag...

Page 13: ...to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are free of dust or debris Product Service If you have any questions about...

Page 14: ...y products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accessories GPS Global Positioning System HighGear Accessories Name Address No P O Boxes City...

Reviews: