background image

Introduction

Introduction

5

4

WARNING: Fire hazard

The jump start feature is designed for short term operation only- less than 5
seconds. Operating the jump start feature for more than 5 seconds may
cause damage to the unit. Allow the power pack to cool down for at least 3
minutes after each jump start.

WARNING: Risk of explosion, fire or burns

The battery terminals exposed at the jump start cable port have enough
energy present to cause a spark, creating an explosion hazard, or to cause
burns if a metal object contacts both terminals. Always clip the plastic guard
over the port when not in use.

CAUTION: Equipment damage

Do not expose the power pack to temperatures over 104° F(40° C) or under 
14° F(-10° C).

Precautions when working with batteries

WARNING: Explosion and fire hazard

1. Follow all instructions published by the battery manufacturer and the

manufacturer of the equipment in which the battery is installed.

2. Make sure the area around the battery is well-ventilated.

3. Never smoke or allow a spark or flame in vicinity of the engine or

batteries.

4. Be careful not to drop a metal object on the battery or allow a metal tool

to simultaneously touch the positive and negative cable ends or battery
terminals. It might spark or short-circuit the battery or other electrical
parts and cause an explosion.

5. Remove personal metal items such as rings, bracelets, necklaces, and

watches when working with batteries. Batteries produce a short-circuit
current high enough to weld a ring or other similar objects to metal,
causing a severe burn.

6. If you need to remove a battery, always remove the negative terminal

from the battery first. Make sure all accessories are off so you don’t cause
an arc.

7. Someone should be within range of your voice, or close enough to come to

your aid when you work near batteries.

8. Have plenty of fresh water, soap and a supply of baking soda on hand in

the area of the batteries in case of contact with battery acid. Baking soda
neutralizes lead acid battery electrolyte.

9. The product is supplied with a rechargeable, sealed lead acid battery. This

battery is self contained and not consumer replaceable.  Batteries must be
disposed of properly when they no longer hold a charge. Proper charging
practices will increase the life of the batteries.
For information on battery recycling call toll free 800-822-8837.

Summary of Contents for CJIC 250

Page 1: ...s for the user Please keep this manual for future reference What s Included with Your CJIC 250 1 Power pack with jump start cables with built in air compressor 2 120V AC charging adapter 3 Owner s operating instructions 4 Inflation nozzles CJIC 250 2009 Cobra Electronics Corporation Version D Printed in China Part No 480 549 P Jump Starter PowerPack with Air Compressor Operating Instructions Intro...

Page 2: ...workmanship and materials for a period of one year from the date of first consumer purchase This warranty may be enforced by the first consumer purchaser provided that the product is utilized within the U S A Cobra will without charge repair or replace at its option defective jump starter power pack products or component parts upon delivery to the Cobra Factory Service department accompanied by pr...

Page 3: ...tires 12 Inflating small sports equipment 13 Jump starting a vehicle s engine 14 Recharging the power pack battery 15 Applications Troubleshooting 16 Specifications 18 Product service 19 Warranty Information 20 Features of This Product 100W AC output for operating household appliances 260 PSI air compressor 12 Volt DC power outlet for DC accessories appliances LED super bright emergency light 5V U...

Page 4: ...roduct to water rain snow condensation or spray Do not open the power pack expect to replace the internal battery Have a qualified technician perform any service work WARNING Explosion hazard Do not use this product where there are flammable fumes or gases such as in the bilge of a gasoline powered boat or near propane tanks Do not use this product in an enclosure containing automotive type lead a...

Page 5: ... not to drop a metal object on the battery or allow a metal tool to simultaneously touch the positive and negative cable ends or battery terminals It might spark or short circuit the battery or other electrical parts and cause an explosion 5 Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries produce a short circuit current high enough to...

Page 6: ...w and two green LED all light 9 Reverse polarity Red LED indicates jump start connection to battery indicator is incorrect 10 120V AC power When this switch is on the 120V AC is available at switch the 120V AC socket 11 120V AC socket Power outlet for AC accessories 12 LED lights Four white LED lights for emergency use 13 12V DC socket Easy access output port to charge 12V accessories Note The uni...

Page 7: ...m the power pack They may have high surge requirements or may be incompatible with the output waveform of the power pack See High Surge Appliances and Trouble Appliances page 10 NOTE To determine required wattage for a device look up required Amps a device is rated This Amperage is found on device I D tag in back of the unit Multiply Amps X Volts Watts Some devices you can power up 13 TV 80W Video...

Page 8: ...ies which can be charged via the USB port of a desktop laptop computer USB chargeable devices usually include a special USB cable not supplied that attaches one end to the USB port and the other end to the device Using the Air Compressor Warning Fire Hazard The compressor is designed for short term operation only Operating the compressor over an extended period of time will cause the compressor un...

Page 9: ...position 14 Remove the adapter 15 Double check the air pressure with a pressure gauge 16 Replace valve stem cap 17 Store the valve connector 13 Inflating small sports equipment You can use the compressor to inflate small sports equipment such as balls soccer balls and footballs Caution The unit cannot be used to inflate large capacity inflatables such as float tubes large air mattresses transport ...

Page 10: ...NG Fire Hazard A reverse polarity connection may cause damage to the unit and or create a sparking explosion hazard Never allow cables red and black clamps to touch each other or another common metal conductor The connection of the cables to the vehicle s battery terminals must be positive to positive red clamp to battery and negative to negative black clamp to battery or vehicle chassis NOTE Care...

Page 11: ...nternal battery is not fully charged Recharge using the AC charger until the charging status LED indicator light green AC appliance power consumption is higher than expected Check AC appliance power or wattage rating or current draw for 12V DC appliance Applications Troubleshooting Troubleshooting Buzzing in audio systems and radios Some inexpensive stereo systems and AM FM radios have inadequate ...

Page 12: ...ower pack is in warranty upon receipt of your unit it will either be repaired or exchanged depending on the model Please allow approximately three to four weeks before contacting Cobra for status If the unit is out of warranty a letter will automatically be sent informing you of the repair charge or replacement charge If you have any questions please call 773 889 3087 for assistance Specifications...