Gas Connection
Gas supply connection point is located 200 mm
from the right hand side, 31 mm from the rear and
124 mm from the floor and is entered from beneath
the appliance.
- Flexible Hose Connection
If a Gas Hose assembly is used to connect this
appliance, the hose and all fittings must have a
minimum
¾
” (Natural Gas) or ½” (LPG) inside bore
diameter to ensure gas flow rate capacity
required by this appliance is achieved.
This must be verified by the operating pressure
testing at the maximum gas supply demand
condition.
The Gas Hose assembly should also be classified
for use in the commercial kitchen conditions, the
appliance will be used in.
CF4 GAS FRYER (Single Tank - 21 Ltr)
Part 2 Specifications
Model Covered in this Specification -
CF4 GAS FRYER (Single Tank - 21 Ltr).
General
A commercial gas fired fryer having a fast fry infra
red burner system which an intense even heat
through the tank.
It is available in single model type. This model fitted
with dual main burners and pilot burners, fitted with
a single gas controller which controls both pilot and
main burners.
This Fryer is fitted with an Over Temperature Safety
Cut Out system with Full Flame Failure Safety
Controls.
Thermostatically regulated gas controls with snap
action thermostat sensitive to changes in oil
temperature which improves both recovery and
output.
An open tank design to make cleaning a simple
and easy task.
Gas Supply Requirements
- Non - UK Only:
- UK Only:
NOTE: (*)
The burner operating pressure is to be measured at
the Outlet Pressure test point on the gas control
valve with both burners operating. The operating
pressure is ex-factory set, through the appliance
regulator and not to be adjusted, apart from when
carrying out gas conversion, if required. Refer to the
‘Gas Conversion Instructions’ supplied with the gas
conversion kit, available on request.
Natural Gas
LP Gas
(Propane)
Input Rating
85 MJ/hr
85 MJ/hr
(N.H.G.C.)
(80,560 BTU/hr)
(80,560 BTU/hr)
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating
Pressure
0.8 kPa (*)
2.5 kPa (*)
Gas Connection
¾” BSP Male
Natural Gas
(G20)
Propane
(G31)
Heat Input (nett)
22.0 kW
22.0 kW
Gas Rate
2.33 m
3
/hr
1.71 kg/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating
Pressure
8.6 mbar (*)
26.4 mbar (*)
Gas Connection
¾” BSP Male