4
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gasses, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using the adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications section of this manual for further details.
Gas supply connection point is located at the rear of the appliance:-
For CB6 -
Approximately 215mm from the left hand side and 535mm from the floor and is entered from
beneath the appliance.
Gas Connection is ½” BSPT male.
For CB9 -
Approximately 215mm from the left hand side and 555mm from the floor and is entered from
beneath the appliance.
Gas Connection is ¾” BSPT male.
LP Gas (Propane)
LP Gas (Butane)
CB6
CB9
CB6
CB9
Input Rating
66.0 MJ/hr
100.0 MJ/hr
66.0 MJ/hr
100.0 MJ/hr
Supply Pressure
2.75 - 4.50 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.60 kPa
2.60 kPa
Gas Connection
½
"
BSPT Male
¾
"
BSPT Male
½
"
BSPT Male
¾
"
BSPT Male
Town Gas (**)
CB6
CB9
CB6
CB9
Input Rating
66.0 MJ/hr
100.0 MJ/hr
66.0 MJ/hr
100.0 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa
0.63 kPa
Gas Connection
½
"
BSPT Male
¾
"
BSPT Male
½
"
BSPT Male
¾
"
BSPT Male