Troubleshooting Guide

Operation

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . 800W
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 1600W
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load) . . . Modified sine wave
Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F)

Storage temperature range . . . . . . . . . . . . -40°C – 85°C

(-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V.

To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for
added safety.

Problem/Symptom

Low output voltage

No output voltage

No output voltage
after prolonged use

No output voltage,
“Protect” indicator
lighted

No output voltage

No output voltage

Low battery alarm
on all the time

Possible Causes

Overload

Low input voltage

Thermal
shutdown

High input
voltage

Short circuit

Inverter
switched

off

No power
to inverter

Reverse
DC polarity

Poor DC wiring

Poor battery
condition

Solution

Reduce the load.

Recharge battery.
Check connections
and cable.

Allow inverter
to cool off.

Reduce load,
continuous
operation input
current required.

Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.

Reduce ambient
temperature.

Make sure
the inverter is
connected to
12V battery.

Check regulation
of charging system.

Check load for
proper operation.

Turn inverter

on

.

Check wiring
to inverter.

Observe
correct polarity.

Check
connections.

Make sure battery
is fully charged.

Troubleshooting Guide

Nothing

Comes Close to a Cobra

®

Summary of Contents for 800 Watt Power Inverter CPI 880

Page 1: ... assistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m CT Monday through Friday except holidays 773 889 3087 phone Questions English and Spanish Faxes can be received at 773 622 2269 fax Technical Assistance English only www cobra com on line Frequently ...

Page 2: ... Ship prepaid and insured by way of a traceable carrier such as United Parcel Service UPS or Priority Mail to avoid loss in transit to Cobra Factory Service Cobra Electronics Corporation 6500 West Cortland Street Chicago Illinois 60707 USA 6 If the power inverter is in warranty upon receipt of your power inverter it will either be repaired or exchanged depending on the model Please allow approxima...

Page 3: ...ent WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are present 2 Do not operate the inverter if it has been dropped or damaged in any way 3 Do not open the inverter it contains no user serviceable parts Attempting to service unit could cause elect...

Page 4: ...and produces a low voltage output If the label on the AC adapter or charger states that it produces a low voltage AC or DC output less than 30 volts the inverter will have no problem powering the adapter safely Cobra 800 Watt Output Waveform Some very sensitive electronic equipment may not operate satisfactory on square wave or modified sine wave The output waveform is referred to as square wave o...

Page 5: ...that ventilation openings on the ends of the unit are not obstructed D Safe Do not install the inverter in the same compartment as a battery or in any compartment that contains flammable liquids such as gasoline E Close to Battery Install unit as close to battery as possible without being in the same compartment to minimize the length of cable required to connect the inverter to the battery It is ...

Page 6: ...s is so it can deliver the maximum amount of energy to the load Only use the cables provided with your power inverter To connect the cables between the inverter and the battery 1 Turn the On Off Switch on the inverter to the off position If the power source is a DC power supply switch it off as well 2 Connect cable to the Power Input Terminals on right side panel of the inverter The red terminal i...

Page 7: ...hat has high power consumption loads It will not operate electric heaters air conditioners stoves and other electrical appliances that consume more than 800 watts CAUTION Loose connectors result in excessive voltage drop and may cause over heated wires and melted insulation CAUTION Reverse polarity connections positive to negative will blow internal fuses in the inverter and may permanently damage...

Page 8: ...ption For each piece of equipment you will be operating from the inverter you must determine the battery s reserve capacity how long the battery can deliver a specific amount of current in automotive batteries usually 25 amperes or ampere hour capacity a measure of how many amperes a battery can deliver for a specified length of time Example Reserve capacity a battery with a reserve capacity of 18...

Page 9: ...tion Operating Limits Operation Operating Limits Power Output The inverter can deliver 800 watts for about 60 minutes The inverter must cool for 15 minutes before it can resume operation at 800 watts Note The wattage rating applies to resistive loads The inverter will operate most AC loads within its power rating Some induction motors used in freezers pumps and other motor operated equipment requi...

Page 10: ...eed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Problem Symptom Low output voltage No output voltage No output voltage after prolonged use No output voltage Protect indicator lighted No output voltage No output voltage Low battery alarm on all the time Possible Causes Overload Low input voltage Thermal shutdown High input voltage...

Page 11: ... This limited warranty does not apply 1 To any product damaged by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs 3 If the serial number has been altered defaced or removed 4 If the owner of the product resides outside the U S A All implied warranties including warranties of merchantability and fitness for a particular purpose are lim...

Reviews: