background image

INSTALLATION MANUAL 4600 CAN/PLIP

22

A.  Power the main unit by connecting the 26 ways connector.
B.  Connect the main unit blue wire to GND (only when a wireless siren is 

fi

 tted).

C.  Open the bonnet. 
D.  Connect the siren blue wire to GND (if not already grounded through the additional bonnet

 

pushbutton).

E.  Disconnect the siren 6 ways connector, then plug it again.
F.  Within 60 s turn the ignition key ON, an audible signal con

fi

 rms that the siren has been stored in the system.

G.  Turn the ignition key OFF and disconnect the BLU wires of the main unit and of the siren from GND (if grounded 

through the additional pushbutton simply open the bonnet).

Check the system functionality arming the system and triggering the alarm to check the proper sounding of the siren.

12. - DOCUMENTS HANDOVER.

Be sure the user manual and the PIN code card is placed in the glove compartment and carry out a full functionality 
demonstration to the customer.

13. - SYSTEM TECHNICAL SPECIFICATIONS.

The manufacturer shall not be liable for any faults or malfunctions in the anti-theft device and/or in the electrical system 
of the vehicle due to incorrect installation and/or to failure to comply with the indicated technical speci

fi

 cations. The 

system must only be considered as a deterrent agaist theft attempts.

TECHNICAL SPECIFICATIONS

 

4600

Rated supply voltage

+12 V DC

Operating voltage

+8 V ÷ +16 V DC

Current consumption (central unit, LED and siren) disarmed                        

8 mA

Current consumption (central unit, LED and siren)  armed 

      

        

12 mA

Central unit operating temperature

- 40 °C + 85 °C

 

Siren operating temperature

- 40 °C + 85 °C

Self power supply

 

Lithium Battery 6 V 1300 mAh

Loudspeaker sound pressure level

 >115 dB @ 1m

Siren sound pressure level  

>114 dB @ 1m

- Central dimensions

91x69x35 mm

- Siren dimensions

113x79x45 mm

Trasmitter battery / Cobra Driver Card

 

Lithium Battery 3 V CR2032

Summary of Contents for 4600 CAN

Page 1: ...4600 CAN PLIP INSTALLATION MANUAL ...

Page 2: ... 5 INSTALLATION PROCEDURE system s component locations electrical connections 5 6 ACTIVE FUNCTIONALITIES descriptions 8 ELECTRIC DIAGRAMS 7 PROGRAMMABLE FUNCTIONS descriptions 18 8 HOW TO PROGRAM FUNCTIONALITIES COBRA REMOTE CONTROLS AND DRIVER CARDS SELF LEARNING PROCEDURE 20 9 FUNCTIONAL TEST 21 10 CAN INDEX MANUAL SELECTION 21 11 SELF LEARNING PROCEDURE REQUIRED TO REPLACE THE MAIN UNIT OR THE ...

Page 3: ...cles with the negative pole connected to the vehicle body HOW TO ACCESS TO THE VEHICLE SPECIFIC TECHNICAL DOCUMENTS DATA LINKER TOOL ANTARES SOFTWARE Access to the web site www cobra at com Installer area and register yourself to be allowed to download the technical documentation Data Linker programming tool and the software Antares are required to customize the product for the destination vehicle...

Page 4: ...click on Application manuals to get the application manual list then download the installation manual of the 4600 for the Plip configuration 3 SYSTEM S CONFIGURATION Be sure to have connected all Data Linker components and to have power supplied the system Run Antares As soon as Antares is starting it automatically checks if the computer is connected to internet if the installed version is the mos...

Page 5: ...ating sources paying attention to keep the main connector oriented down Siren It can be installed in the engine bay as inside the vehicle far away from heating sources paying attention to keep the main connector oriented down Ultrasonic volumetric sensor The ultrasonic transducers must be fixed to the top of the A pillars pointed towards the rear window or to the top of the C pillars pointed towar...

Page 6: ...onnection of compatible Cobra sirens and sensors J 9 and J 10 CAN H L to connect as shown in the specific vehicle CAN installation sheet J 11 Pager negative output low power control signal for triggering a pager device or a telematic one Active low during alarm time J 12 CDL unlock negative output low power control signal to unlock central door locking Activated by the Cobra remote control if prov...

Page 7: ...ower control signal for triggering a pager device or a telematic one Active low during alarm time J 12 CDL unlock negative output low power control signal to unlock central door locking Activated by the Cobra remote control if provided see electrical diagram F J 13 Positive input for CDL motor opening signal to connect as indicated in the specific vehicle PLIP installation sheet or in the product ...

Page 8: ...ming disarming audible signals function has been activated 6 3 Cable cutting protection only for systems with back up battery siren The alarm will trigger if the system is not power supplied cutting of cables battery disconnection signalling the sabotage 6 4 Engine crank inhibition As soon as the system is armed the engine cranking is not possible anymore 6 5 Arming the system with the volumetric ...

Page 9: ...J22 J19 J7 J26 J13 J18 ORANGE VIOLET J25 J12 ORANGE WHITE J11 VIOLET WHITE N O T U S E D J24 BLACK BLACK max 20A 1 sec 6A cont CAN H CAN L 30 See Diagram F See the vehicle fitting instructions or the CAN PLIP J 26 connector pin out See the vehicle fitting instructions or the CAN PLIP J 26 connector pin out HAZARD BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT BLINKER OUTPUT POWER LOGIC SENSOR INPU...

Page 10: ...EN ORANGE WHITE J11 VIOLET WHITE N O T U S E D J24 BLUE J14 J21 15 A Antenna CAN H CAN L max 20A 1 sec 6A cont 30 HAZARD See F Diagram BLINKER OUTPUT BLINKER FEEDBACK BLINKER OUTPUT 30 See the vehicle fitting instructions or the CAN PLIP J 26 connector pin out See the vehicle fitting instructions or the CAN PLIP J 26 connector pin out BLINKER OUTPUT POWER LOGIC SENSOR INPUT 46XX Art WIRELESS SIREN...

Page 11: ...e catalogue between the Ultrasound TX and RX if you don t use the volumetric sensor A WHITE RX Vehicle horn connection with additional relay Original system Additional relay Low power outputs for vehicles with negative CDL control signals Original relay controlled by a negative signal Vehicle horn connection with negative control signal to the original relay 87 30 86 85 87 30 86 85 Y P A S S T X L...

Page 12: ......

Page 13: ...ou with 3 flashes of the direction lights and 3 audible signals 5 audible signals if the arming disarming audible signals function has been activated It also stores in its memory the reason of the occurred alarm and shows it on the emergency panel LED Count the number of flashes and check the corresponding alarm reason on the table By turning the key ON the memory will be deleted LED NUMBER OF FLA...

Page 14: ...IN Code has been digit on the emergency panel This functionality is totally independent from the other ones 7 6 Manual or automatic comfort window closing with Cobra remote control This is a native function of the vehicle so at first check if it is available By keeping pressed the Cobra remote control pushbutton A you can close the windows from a distance in manual mode If not you can ask your ins...

Page 15: ... emergency panel pushbutton Note the product is delivered with this function disabled as its usage invalids the product European homologation It can be used only for non european countries where the functionality is not in conflict with the local regulations 7 8 Garage mode This function allows to temporarily disable all automatic protection functionalities of the system It can be used as an examp...

Page 16: ...re them in the system after few seconds the emergency panel LED will make a quick flash to confirm that the new remote control or the Driver Card has been added to the system All the control devices already stored in the system before entering this procedure must be stored again l If you want to store other remote controls or Driver Cards repeat the procedure at point i The system can store maximu...

Page 17: ...l support could ask you to manually select a different CAN INDEX of the brand which has been loaded in the main unit To select a different CAN application CAN INDEX proceed as follows as soon as the system is powered in the disarming state the emergency panel LED flashes quickly for 5 s during this time frame keep pressed the emergency panel pushbutton until it will go off then release it The LED ...

Page 18: ...IN code card is placed in the glove compartment and carry out a full functionality demonstration to the customer 13 SYSTEM TECHNICAL SPECIFICATIONS The manufacturer shall not be liable for any faults or malfunctions in the anti theft device and or in the electrical system of the vehicle due to incorrect installation and or to failure to comply with the indicated technical specifications The system...

Page 19: ... an independent installation registration system which can be accessed by insurance companies Thatcham administer the Thatcham Recognised Installer scheme on behalf of the British motor insurance industry providing independent registration of installations to vehicle owners Details of the Thatcham Recognised Installer scheme can be found at www thatcham org tri home To ensure consumers insurance c...

Page 20: ...Cobra Automotive Technologies via Astico 41 21100 VARESE ITALY www cobra at com 06DE3325B 10 11 2 32 ...

Reviews: