Chapter 3: Troubleshooting
60
Status signaling
List of alerts
The list below shows the alerts that may appear in the display.
Responsibility transfer:
The Radiotelex accepts responsibility transfer
requests for all category B Warnings via incoming NMEA command from
e.g. a CAM.
Escalation time
: All Warnings are escalated as Warning after 4 minutes.
ID/
Instan-
ce
Prio-
rity
Cate-
gory
Title
Description
Reasons and remedy
3022/1
W
B
AC Power
Outage
AC power outage
has occurred.
Check AC power
distribution.
3023/6
C
B
PS Crosslink
ERR
Power supply
cross link error
Check power supply cross
link
3023/3
C
B
PS COMM
Lost
Power supply
communication
lost.
Check LAN-cable to SAILOR
6081 Power Supply Unit
and Charger. No
communication with the
power supply.
3065/1
W
B
INTERN
TEMP High
Internal power
supply tempera-
ture high
Check the power supply.
3023/1
C
B
BATT VOLT
Low
Battery and
charger. Voltage
below limit.
The battery voltage is
below the limit configured
for the SAILOR 6081 Power
Supply Unit and Charger.
3023/2
C
B
BATT VOLT
High
Battery and
charger. Voltage
above limit.
The battery voltage is
above the limit configured
for the SAILOR 6081 Power
Supply Unit and Charger.
3023/4
C
B
BATT TEMP
High
Battery
temperature
above limit
The battery temperature is
above the configured limit.
Summary of Contents for SAILOR 6000B
Page 1: ...SAILOR MF HF System 6000B User manual Radiotelex...
Page 2: ......
Page 14: ...Chapter 1 Introduction 4 The Radiotelex application...
Page 48: ...Chapter 2 Operation 38 Contacts individual 4 Select OK The contact is now changed in the list...
Page 62: ...Chapter 2 Operation 52 Power status...
Page 72: ...Chapter 3 Troubleshooting 62 Status signaling...
Page 80: ...Index 70...
Page 81: ......