COBHAM AVIONICS WULFSBERG ELECTRONICS
ABBREVIATED COMPONENT MAINTENANCE MANUAL
C406-N (453-5060), C406-N HM (453-5061)
25-62-13
Page 100 of 110
JAN 24/11
SUBTASK 25-62-13-750-001
G. Remote Switch Control Panel Functional Test
(1)
Coordinate functional testing of the remote switch control panel with the post-installation ELT
testing requirements in SUBTASK 25-62-13-750-001, on page 77.
(2)
Place the remote switch in the “ON” position.
(3)
Verify the cockpit remote switch panel light illuminates immediately. If the light fails to
illuminate immediately and stay on steady, recheck the interface wiring and connections
between the ELT and the remote switch control panel.
(4)
Place the remote switch in the “ARM” position.
(5)
Verify the ELT deactivates.