Status signaling with LEDs and status messages
98-165591-B
Chapter 5: Service
5-13
5555
5.3
Status signaling with LEDs and status messages
Built-In Test Equipment
The EXPLORER 6075LX has a Built-In Test Equipment (BITE) function in order to make fault
diagnostics easy during service and installation. The BITE test is performed during:
• Power On Self Test (POST), which is automatically performed each time the system is
powered on.
• Person Activated Self Test (PAST), which is initiated by starting a self test in the web
interface
SERVICE > Self test
.
For details on error messages after a POST or a self test see
Means of signaling
The EXPLORER 6075LX provides various methods for signaling the system status. There are
LEDs
on the front panel of the Base Unit to signal Power on/off, Logon and Fail/Pass. There
is also the built-in web interface of the Base Unit which shows any events (BITE error
codes) with a short message describing each error. This is also displayed in the Base Unit.
In an error situation, one of the following system status messages may be shown:
• ACU POST error
• ADU POST error
• SAFE MODE (plus information about the specific error, see
5.3.1
LEDs on the keypad of the EXPLORER 6075LX
There are 3 LEDs: Power, Logon and Fail/Pass LED.
LED
Behavior
Description
Power
Steady green
Power supply OK
Steady red
Power supply failure
Off
No power
Logon
Flashing green
Current status is displayed:
• Searching satellite
• Identifying satellite
• Carrier lock & Tx enabled from modem
Steady green
Satellite link established
Off
No satellite link acquired