11
represents enter fence alarm; 3 represents out and enter fence alarm.
6.7.5.1 Set up:
the user can send SMS “
spspace++semi-dalarm
type
” to unit to set the restricted district. In case of breach, it will send SMS
“stgeo-info” to the authorized numbers.
For example: send SMS “stockade000000 500 1” stands for based on device
current coordinates as center, 500 is semi-diameter, set 1 as out fence alarm
type.
6.7.5.2 Cancel: Send SMS “
nospassword
” to deactivate this function.
6.7.6 Movement alarm
Device will send movement alarm once vehicle moved 100 meters. The
function is default activate if detected vehicle ACC ON. When vehicle ACC
OFF stands for close movement alarm.
(Note: this function must connect ACC wire ).
6.7.7 Overspeed alarm
6.7.7.1 Set up: Send SMS “
speed+pspace+80
” to the unit(suppose
the speed is 80km/h),and it will reply “speed OK!”. When the target moves
exceeding 80km/h.the unit will send SMS “speed+Geo-info” to the authorized
numbers.
6.7.7.2 Cancel: Send SMS “
speed+pspace+0
” to deactivate the
overspeed alarm.
Remark: It is recommended that the speed alarm is set at not less than