Chapter 2
Chapter 2
Installation
Overview
This chapter contains the following information:
•
Installing the BBG-1040-ACO (p. 2-1)
•
Rear Panel Connections (p. 2-2)
•
Installing the BBG-1040-ACO
Note:
• Where BBG-1040-ACO is to be installed on a mounting plate (or regular
table or desk surface) without optional frame Mounting Tray
BBG-1000-TRAY, affix four adhesive-backed rubber feet (supplied) to the
bottom of BBG-1040-ACO in locations marked with stamped “x”. If feet are
not affixed, chassis bottom cooling vents will be obscured.
• Where BBG-1040-ACO is to be installed with optional frame Mounting Tray
BBG-1000-TRAY, do not affix adhesive-backed feet.
Installing Using BBG-1000-TRAY Optional Mounting Tray
BBG-1000-TRAY
allows up to three BBG-1040-ACO to be mounted and
securely attached to a 1 RU tray that fits into a standard EIA 19” rack
mounting location. Install BBG-1040-ACO unit into tray as described and
shown here.
1.
If installing BBG-1040-ACO using optional frame Mounting Tray
BBG-1000-TRAY, install BBG-1040-ACO in tray as shown in Figure
2-1.
2.
Connect the input and output cables as shown in Figure 2-3.