WEATHERPAK
®
-2000 USER
MANUAL
Coastal Environmental Systems (206) 682-6048
- 1 -
IMPORTANT NOTES
DO CALL/FAX US IF YOU HAVE QUESTIONS OR PROBLEMS
Call Coastal Environmental Systems if any troubles arise or if you have any questions pertaining to the equipment.
Our telephone number is 206-682-6048 and the FAX number is 206-682-5658. Refer to the model number
(WEATHERPAK
-2000) and the serial number of the WEATHERPAK
which can be found by looking under
the radiation shield on top of the unit.
DO WASH OFF CHEMICALS OR DEBRIS WHILE THE WEATHERPAK
IS ASSEMBLED
to prevent
getting water in the connectors. The WEATHERPAK
is water-resistant when assembled.
DO FOLLOW THE MAINTENANCE SCHEDULE.
INCORRECT WIND SPEED WILL RESULT IF THE PROPELLER NUT IS NOT TIGHT.
DO NOT OPEN THE WEATHERPAK
.
It is purged with desiccant bags to seal out all the moisture. Opening
it may allow moisture to foul the electronics and will invalidate the warranty.
DO NOT PICK UP THE WEATHERPAK
BY THE WIND VANE.
This is a durable but sensitive wind
sensor and it can be broken if it is used to lift the entire unit.
DO NOT REMOVE THE ANTENNA FROM THE WEATHERPAK
.
If the WEATHERPAK
is activated
without the antenna, the radio can be damaged.
The WEATHERPAK is designed to be completely automatic. When power is applied, if no terminal intervention
occurs, the system will automatically initialize itself and begin sampling according to its predetermined schedule.
The WEATHERPAK has a hardware clock accurate to about 5 seconds per day and an EEPROM portion of
memory where sampling variables and system parameters are stored. Data are time marked with date/time.
All transient protection sensor signals and power lines are protected from transients and EMI by circuitry inside the
WEATHERPAK. EMI filters are single pole RC filters (100 ohm and 0.1 microfarads). Transient protection is by
18 volt tranzorb diodes. If for any reason -- lightning, RF interference, power surge -- the computer program is
corrupted and the sampling loop is broken, then a watchdog timer will reset the entire system and the
WEATHERPAK will go into its autoboot routine.
DEPENDING ON YOUR CONFIGURATION THIS USER MANUAL CONTAINS
INFORMATION THAT MAY NOT APPLY TO YOUR SPECIFIC WEATHERPAK.