CODE DESCRIPTION
TROUBLE SHOOT
E4
Spider not going up to home
position on power up.
Upon power up, the string
goes down, then goes up, but
Upper stop SW does not
receive a signa
l
Press TEST SW for test mode and check.
The possible reasons:
1.
UP/DOWN string reversed.
2.
Upper stop SW breakdown, harness
disconnected, or bad connection.
3.
F2 FUSE burned. UP/DOWN motor fuse
burned.
4.
Check if gantry JP1 harness pin
disconnected.
5.
Main board failure.
E5
Coin mech error
On power up, the coin mech is signal checked
automatically. E5 is displayed when set into
N.C.
1.
Check the N.O./N.C. SW and restart game
after set to N.O.
2.
Coin mech failure.
3.
Main board failure.
E6
TICKETS OUT ERROR
Press CLEAR to restart ticket dispenser.
E9
Spider not returning to
home position on power
up.
E9 is displayed. The game will still start after
coin in. E9 will clear after 3 attempts.