Error Codes and Troubleshooting
Error Code
Description
Out of Service
1
Communication to DLP Radio Board
Yes
2
Internal DLP Module Error
Yes
3
Out of Tickets
Yes
4
Bucket Door Error
Yes
E1: Communication to DLP Board
Troubleshooting
:
Check Ground wire is plugged in on board properly.
Check Harnessing down to the Timer Board.
E2: Internal DLP Module Error
Troubleshooting
:
Check you have correct version of board installed.
Check for damage on board.
E3: Out of Tickets
Troubleshooting
:
Check Ticket Bin(s) are restocked with tickets.
Check that Dispenser is plugged in.
Check Notch line for shorts.
E4: Bucket Door Error
Troubleshooting
:
Check the switch inside RFID box.
Trace wires for shorts.
Check motor for damage.
Check motor harness for damage.