OWNER’S MANUAL 

2017 

SYMPTOM  PROBABLE CAUSE 

RECOMMENDED ACTION 

 

No message on display.  
Power has been cut off to the spa. 

The control panel will be disabled until power returns. Spa settings will be 
preserved until next power up. 

- -  

Temperature unknown. 

After the pump has been running for 2 minutes, the current water tempera-
ture will be displayed. 

HH 

“Overheat” - The spa has shut down.* One of the sen-
sors has detected 118°F/47.8°C at the heater. 
 

DO NOT ENTER THE WATER. Remove the spa cover and allow water to 
cool. Once the heater has cooled, reset by pushing any button. If the spa 
does not reset, shut off the power to the spa and call your dealer for service 
organization 

OH 

“Overheat” - The spa has shut down.* One of the sen-
sors has detected that the spa water is 110°F/43.5°C. 
 

DO NOT ENTER THE WATER. Remove the spa cover and allow water to 
cool. At 107°F/41.7°C, the spa should automatically reset. If spa does not 
reset, shut off the power to the spa and call your dealer or service organiza-
tion 

SA 

Spa is shut down.* The sensor that is plugged into the 
Sensor “A” jack is not working. 

If the problem persists, contact your dealer or service organization. (May 
appear temporarily in an overheat condition) 

Sb 

Spa is shut down.* The sensor that is plugged into the 
Sensor “B” jack is not working. 

If the problem persists, contact your dealer or service organization. (May 
appear temporarily in an overheat condition) 

Sn 

Sensors are out of balance. If alternating with spa tem-
perature, it may just be a temporary condition. If flashing 
by itself, spa is shut down. 

If the problem persists, contact your dealer or service organization.  

HL 

A significant difference between temperature sensors 
has been detected. This could indicate a flow problem. 

If the water level is normal, make sure all pumps have been primed.  If prob-
lem persists contact your dealer or service organization. 

LF 

Persistent low flow problems. (Displays on the fifth oc-
currence of  message within 24 hours.) Heater is shut 
down, but other spa functions continue to run normally. 

Follow action required for (HFL) message. Heating capability of the spa will 
now reset automatically.  You may press any button to reset. 

dr 

Possible inadequate water, poor flow, or air bubbles in 
detected in the heater. Spa is shut down for 15 minutes. 

If the water level is normal, make sure all pumps have been primed.  If prob-
lem persists contact your dealer or service organization. 

dY 

Inadequate water detected in heater. (Displays on third 
occurrence of  message.) Spa is shut down.* 

Follow action required for (dr) message. Spa will not automatically reset. 
Press any button to reset manually. 

IC 

“Ice” - Potential freeze condition detected.  
*Even when spa is shut down, some equipment will turn 
on if freeze protection is needed. 
 

No action required. All equipment will automatically activate regardless of 
spa status. The equipment stays on 4 minutes after the sensors detect that 
the spa temperature has risen to 45°F/7.2°C or higher. An optional freeze 
sensor may be added to protect against extraordinary freeze conditions. 
Auxiliary freeze sensor protection is advisable for colder climates. See your 
dealer for details. 

TOPSIDE CONTROLS |  DIAGNOSTIC MESSAGES 

Summary of Contents for Coast Spas with hydro Cyclonic Filtration Sydtem

Page 1: ...1 VERSION 01152016 Coast Spas Manufacturing Inc 6315 202 Street Langley BC Canada 604 514 8111 info coastspas com www coastspas com ...

Page 2: ...e 8 Draining Winterizing Page 8 Filter Maintenance Page 9 Water Quality Maintenance Page 9 10 MicroSilk Information Page 10 Water Clarity Troubleshooting Page 11 Product Care Guide Page 12 13 Glossary of Terms Page 13 14 Troubleshooting Guide Page 15 16 Spa Controls Page 17 18 Coast Elite Series Controls early 2016 Page 19 27 Coast Luxury Series Controls Page 28 37 Installation Service Information...

Page 3: ...3 ...

Page 4: ...accessories The Coast Connect Universal Fitting is installed flush to the spa floor and supplies both light and water to the connected accessory Image installed Accessory Connection Place male accessory connection into female Universal Fitting Twist clockwise to connect and secure Twist counter clockwise to disconnect and remove ...

Page 5: ...5 ...

Page 6: ...6 ...

Page 7: ...y of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a hot tub CAUTION Risk of Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the OWNER S MANUAL 2017 normal body temperature of 98 6 F 37 C The symptoms of hyperther mia include drowsiness lethargy and an increas...

Page 8: ...el surface so the spa weight is supported uniformly We recommend no less than a 3 93 mm thick concrete slab Wood decking or balconies must be con structed to support 150 pounds per square foot 730 kg m Refer to local and current building codes in your area Consult an engineer for live loads in your area Should your new spa need to go through a gate the opening should be a minimum of 48 inches and ...

Page 9: ... minerals and or oils Rinse filter thoroughly before installing Clean o ring on filter lid and apply a light film of silicone lubricant to the o ring Do not use a petroleum based lubri cant as it could damage the o ring Consult your dealer to purchase suitable lubricant Place clean Cartridge in filter canister Replace filter lid and re tighten retaining ring finger tight only OWNER S MANUAL 2017 N...

Page 10: ...f the water Your Authorized Dealer can advise you on the use of these additives OWNER S MANUAL 2017 MICROSILK If your hot tub is equipped with a MicroSilk generator you can take ad vantage of some incredible health and appearance benefits Find ex panded information below on the Microsilk system benefits and opera tion ABOUT MICROSILK MicroSilk produces a silky white cloud of micro bubbles that are...

Page 11: ...o low pH is too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Cloudy Water Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water Algae Growth pH is too high Sanitizer is too low Adjust pH Shock spa with sanitize...

Page 12: ...ediately until the water has been restored to suggested conditions Do not sit on the pillows OWNER S MANUAL 2017 Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time you drain you spa HOT TUB INTERIOR Your hot tub has a fiberglass reinforced acrylic shell Generally dirt and stains will not ...

Page 13: ... the fluid used in cigarette lighters Use sparingly then immediately apply conditioner to that area GLOSSARY OF TERMS AIR CONTROL VALVE Mounted generally on the lip of the spa it in duces warm air from the equipment enclosure into the jet stream through venturi action WATER DIVERTER VALVE The large diverter is used to divert water to various seats in the spa OWNER S MANUAL 2017 ON OFF DIVERTER VAL...

Page 14: ...ge ADJUSTABLE CLUSTER JET Our adjustable high intensity hydro therapy jet DIRECTIONAL JET Provides a straight flow for a therapeutic massage ROTATIONAL JET Provides a Uni directional circular therapeutic mas sage MASSAGE JET Delivers massage in staccato bursts over a narrow focused area VOLCANO WHIRLPOOL JET high output jet designed for foot and leg massage LAMINAR FLOW WATER FEATURE A thin stream...

Page 15: ...Pump running constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Deal...

Page 16: ...periods of time in cold weather cold wind Hot tub is wired for 110V and jets are on Put cover back onto hot tub and allow for heat to regenerate Call your dealer if temperature does not increase Hot tubs wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No...

Page 17: ...e panel however you will still be able to control the high speed setting The ozone generator if installed will activate anytime low speed is run ning AUX PUMP 2 If an additional pump or blower is installed Press Aux to turn the de vice on If your additional device is a dual speed pump pressing Aux OWNER S MANUAL 2017 again will activate the pumps high speed Pressing Aux again will turn off the dev...

Page 18: ...e a temporary condition If flashing by itself spa is shut down If the problem persists contact your dealer or service organization HL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all pumps have been primed If prob lem persists contact your dealer or service organization LF Persistent low flow proble...

Page 19: ...Press any button on the screen to wake the panel up NAVIGATION Navigating the entire menu structure is done with the 5 buttons on the control panel When a text item changes to white during navigation that indicates the item is selected for action Operating or changing a selected item is generally done with the center or Select button The only item that can be changed on the left side of the Main S...

Page 20: ...s where all programming and other spa behaviors are controlled This screen has several features that can be acted on directly These features include Temp Range Heat Mode and Invert Panel When one of these items is highlighted the Select Button is used to toggle between two settings All other menu items with an arrow point ing to the right go to another level in the menu PRESS AND HOLD If an Up or ...

Page 21: ...ng the heater under low flow or no flow conditions Nothing comes on auto matically but the pump s can be energized by selecting the Jet but tons If the spa has a Circ Pump it can be turned on and off by press ing the Circ Pump button during Priming Mode In addition if the spa has a Circ Pump it can be activated by pressing the dedicated Light button during Priming Mode Manually exit Priming Mode b...

Page 22: ... one filter cycle that will run in the evening assuming the time of day is properly set when energy rates are often lower The filter time and duration are programmable A second filter cycle can be enabled as needed FREEZE PROTECTION If the temperature sensors within the heater detect a low enough tem perature then the water devices automatically activate to provide freeze protection The water devi...

Page 23: ...manner with each button press RESTRICTING OPERATION The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features to be used but the Set Temperature and other programmed settings cannot be adjusted Settings Lock allows access ...

Page 24: ...lighted the detail for that item is displayed at the bottom of the screen Software ID SSID Displays the software ID number for the System System Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for the system configuration file Heater Wattage as Configured in Software Displays a heat...

Page 25: ...ze pro tection is needed M0XX is a Message Code Codes like this will be seen in the Fault Log Some messages can be reset from the panel Messages that can be reset will appear with a right arrow at the end of the message Press the message text to reset the message SENSOR RELATED MESSAGES SENSORS ARE OUT OF SYNC M015 The temperature sensors MAY be out of sync by 3 F Call for Service SENSORS ARE OUT ...

Page 26: ...sionally to maintain proper spa function and sanitary con ditions Additional messages may appear on specific systems Reminder messages can be reset from the panel Messages that can be reset will appear with a right arrow at the end of the message Press the message text to reset the message Warning Qualified Technician Required for Service and Installation BASIC INSTALLATION AND CONFIGURATION GUIDE...

Page 27: ...ite du disjoncteur differentiel avant d utiliser differentiel avant d utiliser le bain Lire la notice technique Lorsque l appareillage est installe dans une fosse on doit assurer un drainage adequat Employer uniquement a l interieur d une cloture CSA Enclosure 3 Connecter uniquement a un circuit protege par un disjoncteur differen tiel de Class A Afin d assurer une protection permanente contre le ...

Page 28: ...ns time out and revert to the main screen after 30 sec onds of no activity OWNER S MANUAL 2017 The only item that can be changed on the left side of the Main Screen is the Set Temperature Touch either the set temperature line or the water temperature to go to the Set Temperature screen MESSAGES At the bottom of the screen messages may appear at various times Some of these messages must be dismisse...

Page 29: ...ave changed the value on that screen If the screen times out due to no activity it will act like Cancel When you see only this button whether it is labeled or not it means Back or Exit It appears on editing screens before you have changed any value as well as on all other screens OWNER S MANUAL 2017 PAGE UP DOWN If an Up or Down button is shown and pressed when in a Menu List the list can be scrol...

Page 30: ...il the heater pump has been running for a minute or two When the heater pump has come on automatically for example for heating you can switch between low speed and high speed but you cannot turn the heater pump off OWNER S MANUAL 2017 CIRCULATION MODE If the spa is configured for 24HR circulation the heater pump generally runs continuously Since the heater pump is always running the spa will maint...

Page 31: ...re polling and then to heat to the set temperature if needed When the low speed turns on automatically it cannot be deactivated from the panel however the high speed may be started CIRCULATION PUMP MODES If the system is equipped with a circ pump it will be configured to work in one of three different ways 1 The circ pump operates continuously 24 hours with the exception of turning off for 30 minu...

Page 32: ... may be manufactured with Circ Pump settings that allow programming filtration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s documentation for any Circ Mode details PURGE CYCLES In order to maintain sanitary conditions as well as protect against freez ing secondary water devices will purge water from their respe...

Page 33: ...t says On or Panel if it says On than press in the middle of the screen for at least 5 seconds OWNER S MANUAL 2017 SCENES WHAT ARE SCENES Scenes are stored combinations of equipment states For example if you want to have Pump 1 at high speed and Pump 2 at low speed and the Light ON you could store that in a Scene and recall this combination at any time STORING A SCENE Press a Scene number and hold...

Page 34: ...0XX is a Message Code Codes like this will be seen in the Fault Log ADDITIONAL SETTINGS PREFERENCES The Preferences Menu allows the user to change certain parameters based on personal preference TEMP DISPLAY Change the temperature between Fahrenheit and Celsius TIME DISPLAY OWNER S MANUAL 2017 Change the clock between 12 hr and 24 hr display REMINDERS Turn the reminder messages like Clean Filter O...

Page 35: ...e GFCI with its own test button Restore power to the spa and repeat the GFCI Trip Test Once the GFCI is tripped by the test reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the above menu Passed should appear after the Reset line is selected on the GFCI screen WARNING On those systems that automatically test the GFCI within 1 to 7 d...

Page 36: ...for Service MISCELLANEOUS MESSAGES COMMUNICATIONS ERROR The control panel is not receiving communication from the System Call for Service TEST SOFTWARE INSTALLED The Control System is operating with test software Call for Service OWNER S MANUAL 2017 F OR C IS REPLACED BY T The Control System is in Test Mode Call for Service M0XX is a Message Code Codes like this will be seen in the Fault Log SYSTE...

Page 37: ...upter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa hot tub and in line of sight from the equipment compartment OWNER S MANUAL 2017 CSA ENCLOSURE TYPE 2 Refer to Wiring Diagram inside the cover of the control enclosure Refer to Installation and Safety Instructions provided by the spa manufacturer Warning People with infectious diseases should not use...

Page 38: ...ater in your spa MODEL ST1 REGISTRATION NUMBER 27899 02 PEST CONTROL PRODUCTS ACT SECTION 01 Introduction Important Safety Instructions Health General Hyperthermia Important Information SECTION 02 Specifications SECTION 02 Preparation Monitoring Operation Boost Option Power Supply Cell Installation SECTION 04 Troubleshooting ...

Page 39: ...t tub may be dangerous to your health OWNER S MANUAL 2017 WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spa or hot tub without permanent adult supervision WARNING Risk of Accidental Drowning Extreme caution must be exer cised to prevent unauthorized access by children To avoid accidents ensure...

Page 40: ...low the unit to receive power 24hrs a day Once this is connected and pump 1 is running you will see the ozone knob glow with a slight blue green tinge The Eco Clean light will also begin to blink Green for up to 30 seconds During this time the EcoClean is measuring the salt content of the water OWNER S MANUAL 2017 4 If the light stays Green then the unit is now running and converting salt to sanit...

Page 41: ...DC Plug burned The cell cord plug is not securely pushed onto the power supply allowing moisture to seep into the plug Completely failed cell Ensure that the cell cord plug is pressed completely on the power supply Replace the cell White flakes in the water This occurs when excessive calcium hardness is pre sent in the water being sanitized This should cease after a few days Monitor the pH and adj...

Reviews:

Related manuals for Coast Spas with hydro Cyclonic Filtration Sydtem