OWNER’S MANUAL
SWIM SPAS
2021
21
before they’re thoroughly rinsed. Now apply the vinyl conditioner
as directed on the container. Massage the conditioner into the
cover in a gentle but firm manner. Before replacing the cover on
your spa, wipe and rinse any dirt from the bottom of the cover.
When you are ready, put the cover on the spa.
NOTE:
To remove tree sap, use lighter fluid (not charcoal
lighter but the fluid used in cigarette lighters). Use sparingly,
then immediately apply conditioner to that area.
All waterfalls and laminar flow water features should be turned
off when the spa is not in use to avoid heat and water loss.
BASIC INSTALLATION AND CONFIGURATION
GUIDELINES
WARNING! Qualified Technician Required for Service and
Installation
ELECTRICAL REQUIREMENTS
All self contained spas use 120VAC or 240VAC electrical spa
packs. These instructions describe the only acceptable electrical
wiring procedures. Spas wired in any other way will void your
warranty and may result in serious injury. All installations should
be completed by a certified electrician. Failure to comply with state
and local codes may result in fire or personal injury and will be the
sole responsibility of the spa owner.
120VAC:
This requires an isolated 15 Amp circuit breaker.
This needs to be an isolated circuit with no other appliances or
lights on this circuit at any time. Extension cords are not to be used
in conjunction with the operations of the spa. Low voltage damage
could result and this is not covered by warranty.
NOTE:
All components must be 120V; No 240V components
allowable.
240VAC:
Depending on the model of spa, it will require either
a 40 Amp, 50 Amp, or 60 Amp dedicated circuit breaker, GFCI,
with the proper wire size based on the length of the run. The
electrical circuit must be installed by a certified electrician and
approved by a local building or electrical inspector.
SWIM SPAS AMP CHART
Series
Pumps
Voltage
Amperage
Frequency Circuit Breaker Max Flow Rate
Base Series
1 x 4HP
240
40
60
50
91
Play Series
1 x 4HP + 1 x 4HP Viper
240
40
60
50
91
Performance Series
2 x 4HP Viper + 1 x 5HP
240
40
60
50
91
Wellness Spa Series -
1400VE
2 x 4HP Viper + 1 x 5HP
240
40
60
50
91
Wellness Spa Series -
1303B/L | 1700VE |
2100VE | 1600
3 x 4HP Viper + 1 x 5HP
240
48
60
60
91
Wellness Performance
Plus (W/VSP)- 1400VE
1 x 5HP + 2 x VS
240
48
60
60
91
Wellness Performance
Plus (W/VSP)-
1700 VE | 2100 VE
1 x 5HP + 3 x VS
240
48
60
60
91
DISCLAIMER: There are no user serviceable parts in the GFCI compartment. All the services and repairs should be
performed by a certified electrician only.
*Always use seimens breaker for Waterway packs. No Exception.