Coast-Air CEG-123A Installation And Operation Instruction Manual Download Page 5

CEG-81A & CEG-123A

Installation and Operation Instruction Manual

4

5

www.coastair-ac.com

4

INSTALLATION  INSTRUCTIONS

CAUTION

To avoid risk of personal injury, property damage, or product damage due to the weight of this device       

and sharp edges that may be exposed:

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are           

needed to move and install the unit.

 

To prevent injury or strain, use proper lifting and carrying techniques 

when moving unit.

C

arefully inspect location where air conditioner will be installed. Be sure it will support the weight of   the 

unit.

Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the 

sharp metal fins of front and rear coils.

Make sure air conditioner does not fall during installation.

Tools and Parts:

Gather the required tools and parts before starting installation. Read and follow the instructions 

provided with any tools listed here.

TOOLS  NEEDED

Flat-blade and Phillips screwdrivers

Tape measure

Level

Drill and 3/16 , 1/8 , 3/32 , or smaller drill bit

Through-the-wall Installation:

In addition to the tools listed above, the following tools are needed for through-the-wall installation.

TOOLS  NEEDED

Saw

Caulk

1  (2.5 cm) or thicker lumber

#10 X 1  wood screws (7)

Parts Supplied:

Check that all parts are included in parts package:

Hardware

Qty.

3

7

#10 X 1/2" 

pan - head

 

Phillips

 

screws

Qty.

1

1

round - head screws

pan - head

Phillips screws

5

Top channel

Window sash seal

Hardware

Foam seal

1

side curtains

2

5

1

2

Window lock bracket

Safety Lock

(for Vinyl-Clad window)

weather seals

Remote Control

1

Remote Battery

2

MO

DE

ENERG

Y

 S

A

V

ER

CLEAN

 AIR

F

OLLOW

 ME

S

LEEP

LED

CLOCK

CAN

CEL

TIMER

FA

RESET

LOCK

C

L

O

C

K

E

O

N

 O

F

F

S

E

T

 T

E

M

P

.

F

A

N

 S

P

E

E

D

AUTO

F

1 2

or

Summary of Contents for CEG-123A

Page 1: ...Installation and Operation Instruction Manual Room Air Conditioner CEG 81A CEG 123A www coastair ac com ...

Page 2: ...se it may cause electric shock or fire due to excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric sho...

Page 3: ... fire or electric shock Operation without filters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure Hold the plug by the head of the power plug when ta...

Page 4: ...net and behind the grille If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manua...

Page 5: ...ot fall during installation Tools and Parts Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here TOOLS NEEDED Flat blade and Phillips screwdrivers Tape measure Level Drill and 3 16 1 8 3 32 or smaller drill bit Through the wall Installation In addition to the tools listed above the following tools are needed for throu...

Page 6: ...air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently 1 Remove the air conditioner from the carton and place it on cardboard 2 Remov...

Page 7: ...ndow 1 Locate provided bag of screws 2 Place the top channel on top of the air conditioner cabinet lining up the three holes in the top channel with the three holes on top of the air conditioner cabinet 3 Using three pan head Phillips thread cutting screws attach the top channel to the air conditioner cabinet A B B Top channel FIG 6 O thread cutting screws NOTE FIG 7B Top view A B FIG 7A A B FIG 7...

Page 8: ...For Vinyl Clad window Use a 1 8 drill bit to drill one hole through the hole in the middle of top rail and into the window frame Attach cabinet to window with one 10 x 3 4 or 1 2 round head Phillips screw FIG 11 Place two safety locks into the holes that located in the bottom of the cabinet and drive two locking screws through the safety locks into the cabinet as shown FIG 12 1 1 3 Check that air ...

Page 9: ... and swing front into place 7 Attach bottom front of panel with front panel screws FIG 17 8 Plug into a grounded 3 prong outlet 9 Press RESET on the power supply cord Through the Wall Cabinet Installation Option 1 wood metal or plastic molding When using a wood metal or plastic molding the wood frame should line up with the inside wall as shown FIG 18 Option 2 Plastered wall with no molding If the...

Page 10: ...tilted to the outside so that water can run to the outside The cabinet should slop at least half a bubble towards the rear 4 Reuse the insulation to seal opening between cabinet and frame 5 Use existing holes in sides and top of cabinet and seven 10 X 1 wood screws not provided to attach cabinet to frame 6 Caulk all outside wall openings around cabinet Do not overtighten screws or the cabinet will...

Page 11: ...ure is seen on the display This temperature will be automatically maintained O O O O anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To Operate on Fan Only section Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter High efficiency compressors may have a high pitched...

Page 12: ...d for 6 hours before it returns to the originally selected temperature This ends the Sleepmode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again Press Check filter button to initiate theis feature This feature is a reminder to clean the Air Filter for more efficient operation The LE...

Page 13: ...eaker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds 12 Air Directional Louvers Air Direction 4 way The 4 way air directional louvers allow you to direct the air flow Up or Down on some...

Page 14: ...es common occurrences that are not the result of defective workman ship or materials in this appliance Solution Air conditioner does not start Wall plug disconnected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem Air from unit does not feel cold enoug...

Page 15: ...rns on and off rapidly Noise when unit is cooling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty air filter air restricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set...

Page 16: ...is proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement product is no longer available during the warranty period Coast...