STOVE CAN BE INSTALLED AS A TOP OR

BACK FLUE APPLIANCE.

The Severn Stove is intended to provide space heating

only

. The appliance and burning rate are controlled by

the manual adjustment setting of the sliding levers only
at the bottom of each firedoor.

Rating

Space Heating

15kW (50,000 Btu/h)

For correct operation of the appliance, the height of the
chimney from its base should not be less than 5.5m and
terminate above the roof in accordance with current
Building Regulations and regional statutory requirements
as outlined in BS 6461 Parts 1 and 2.

The structural flue through the chimney should not be
less than 200mm diameter. Pargeted lined flues,
228mm x 228mm must be in sound condition, and any
internal offsets should not be less than 60

˚

 to the

horizontal. Check that the flue exit is not obstructed or
reduced in size.

IMPORTANT:

FAILURE TO OBSERVE THE

RECOMMENDED MINIMUM SIZES OR METHODS OF
FLUE CONNECTION MAY LEAD TO FUME EMISSION
INTO THE ROOM AND REDUCED BURNING RATES.

The internal and external condition of the chimney
should be checked 

before

the appliance is installed and

rectified where necessary to prevent air leakage or
porosity.

9/00 EINS 33742

Installation Instructions

for Freestanding

Severn Stove

Consumer Protection Act 1987

As manufacturers and suppliers of cooking and heating products, in
compliance with Section 10 of the Consumer Protection Act 1987,
we take every care to ensure, as far as is reasonably practicable, that
these products are so designed and constructed as to meet the
general safety requirement when properly used and installed. To this
end, our products are thoroughly tested and examined before
despatch.

IMPORTANT NOTICE:

Any alteration that is not approved by Aga-

Rayburn, could invalidate the approval of the appliance, operation of
the warranty and could also affect your statutory rights.

Control of Substances - Health & Safety
Important

This appliance may contain some of the materials that are indicated
below. It is the Users/Installers responsibility to ensure that the
necessary personal protective clothing is worn when

handling where applicable, the pertinent parts that contain any of the
listed materials that could be interpreted as being injurious to health
and safety, see below for information.

Firebricks, Fuel beds, Artificial Fuels - 

when handling use

disposable gloves.

Fire Cement

- when handling use disposable gloves.

Glues and Sealants

- exercise caution - if these are still in liquid

form use face mask and disposable gloves.

Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil 

- may be harmful if inhaled, may be irritating to skin,

eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face-masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product, reduce dust with water water spray,
ensure that parts are securely wrapped. 