7. Changing planing irons
1. Planing irons can be sharpened (HSS) up to three times (3 × 0.05 mm):
2. Remove the angle stop and lift up the arm holding the cover.
3. Turn the cutter by hand until one of the iron’s tightening screws is visibly turned upwards.
4. Loosen the four screws on the steel holder (which press the planing iron against the cutter) with
the accompanying Allen keys.
5. Remove the planing iron and steel holder out of the slot on the cutter. With an oiled cloth, clean the steel
holder, slot and planing iron, removing waste, shavings and dust.
6. Sharpen the planing iron or change it. Put the planing iron and steel holder in the slot again and lock them in
place by turning the tightening screws clockwise (but do not tighten fully), make sure the planing iron is lying
against the cutter allowing the two adjusting screws to fit into their notch in the planing iron.
7. Adjust the edges sticking out with the accompanying 4 mm Allen keys by turning the steel holder’s
two adjusting screws in and out according to requirement. After setting correctly, tighten the fastening
screws again.
8. Check how much cutter steel sticks out above the outflow table with a template or ruler on the outflow
table. The maximum protrusion over the outflow table is: 0.1 mm. (measure several times over the width of
the whole planing blade).
9. Tighten the screws and measure the edges sticking out again after tightening.
Attention!
Do not use a key
with a longer shaft than the one delivered.
10. Repeat the procedure with the other planing iron, then check that both planing irons stick out the
same amount.
8. Raising and lowering planing table
Take out the crank and mount it on the axle on the above side of the plane, turn the crank until it goes down
and locks tightly on the axle; remove after setting.
9. Mounting the planer/thickesser on a bench etc.
The level and surface plane should be mounted on a stable bench, table etc. The plane weighs 26 kg and
should be fastened to a hard, flat surface. It has four fastening holes (Ø 9 mm). Fasten the plane with M8 bolts,
washers and locking bolts (not included).
240 mm
350 mm
4 × Ø 9 mm
10. Wiring diagram
M
Overload protection
230 V~
NVR switch