background image

GREAT BRITAIN • CUSTOMER SERVICE

  tel. 0845 300 9799  e-mail [email protected]  internet www.clasohlson.com/uk

360

MENY     SET

    →      

+

 

RST

 

 

W

COST

I.68

TARIF

0.50

kWh

I234.56

W

3680

3680

VA

230.00

V

I6.00

A

50.00

Hz

0.99

PF

8888.8.8

V Hz
A VA
W PF
kWh

COST      TARIFF

Ver

. 20140214

Plug-In Electricity Meter

Art.no 18-2027  Model  EMT707CTL-UK
 

36-2897  

EMT707CTL

Please read the entire instruction manual before 
use and save it for future reference. We reserve 
the right for any errors in text or images and for 
making any necessary technical changes to this 
document. If you should have any questions 
concerning technical problems please contact 
our Customer Services. 

Safety

• 

The product is intended only for use indoors.

• 

Devices connected to the electricity meter 
should be of the same power rating and 
specifications.

Product Description

The electricity meter measures how much ener-
gy an electric device uses. The electricity meter 
can calculate the total cost of running a device 
if the price of each KWh is entered. The display 
shows, amongst other things, the voltage, po-
wer, energy consumption, kWh, and the resistive 
load (VA) of the connected device. This product 
should be connected to an earthed socket.

Buttons

• 

[ MENU ] Press to view 
cost, tariff, kWh, VA, 
Volts, Amps, Hz and 
power factor.

• 

[ SET ] Use to set 
the tariff and kWh.

• 

 ] Use to change 

settings.

• 

[ + ] Use to change 
settings.

• 

[ RST ] Hold in this 
button to reset the unit 
to its factory settings. 
Cost, tariff and kWh 
are not reset.

Guide to the functions

Press the [ MENU ] button to view the functions 
in the following order:

1.  COST

Shows the present 
load.

Shows the total cost 
(up to 9999.99).

2.  TARIFF

Shows 
the programmed tariff.

3.  kWh

Shows the total 
consumption in kWh.

4.  W

Shows the present 
consumption in Watts. 

NB:

 The minimum unit 

of power that can be 
measured is 5 W.

5.  VA

Shows the  
reactive power.

6.  V

Shows the voltage of 
the power supply.

7.  A

8.  Hz

Shows the frequency of 
the power supply.

9.  PF

Shows the power factor.

10. RESET

When the unit is reset, 
all the symbols will be 
displayed for a brief 
moment.

Setting the electricity meter

1.  Connect the electricity meter to an earthed 

wall socket. The electricity meter will start 
and for a moment all the symbols will appear 
on the display.

2.  After about 3 seconds the electricity 

meter will enter the cost mode (fig.1) 
and the display will show the latest cost 
calculation.

3.  Press [ SET ] once. “TARIFF” will appear on 

the display and the right-hand digit will flash.

4.  Press [ 

 ] to choose which digit you wish 

to set.

5.  Press [ + ] to set the value of the digit that 

flashes. Press [ 

 ] once again to choose 

the next digit you wish to set.

6.  Press [ SET ] to show and set the value 

the measurement of kWh is to start at. 
The default setting is 

0

, but this can be 

changed if you wish to set the electricity 
meter to the same setting as an existing 
electricity meter.

7.  Set the kWh as instructed above.
8.  When you have set the electricity meter, plug 

in the device you wish to measure. Metering 
begins at once.

Care and Maintenance

Always remove the electricity meter from the wall 
socket before cleaning it. Wipe with a soft, lightly 
moistened cloth.

Disposal

Follow local ordinances when disposing of this 
product. If you are unsure about how to dispose 
of this product contact your municipality.

Specifications

Current 

230 V AC, 50 Hz

Power 

3680 W

Minimum power unit 

5 W

Measuring Ranges 

110–300 V 

 

5–4800 VA (3600 W) 

 

0.02–16 A

Operating Temperature 

−20 to 40 °C

Accuracy

≤ ± 5.0 %

≤ ± 5.0 %

Hz 

≤ ± 0.2 %

≤ ± 5.0 %

VA 

≤ ± 5.0 %

kWh 

≤ ± 1.0 %