CO/Tech D10-023N0-027 Instruction Manual Download Page 1

GREAT BRITAIN • CUSTOMER SERVICE

  tel. 020 8247 9300  e-mail [email protected]  internet www.clasohlson.co.uk   

postal 10 – 13 Market Place, Kingston Upon Thames, Surrey, KT1 1JZ

Ver

. 20170927

LED Downlight

Art.no  36-6826 

Model  D10-023N0-027

Please read the entire instruction manual before using the product and then 
save it for future reference. We reserve the right for any errors in text or 
images and any necessary changes made to technical data. In the event of 
technical problems or other queries, please contact our Customer Services.

Safety

Symbol description

Warning for a possible 
hazard which could lead to 
serious personal injury and/
or damage to the product if 
the stated instructions are 
not followed.

Warning for an electrical 
shock hazard.

The fitting should not be 
covered with any heat 
insulating material.

Class II product. 
Double-insulated.

Only intended for 
indoor use.

The product is not 
dimmable.

Safety instructions

• 

This product must only be installed by a qualified electrician.

•  Before beginning any electrical installation always disconnect the power 

to the circuit you are working on, either by turning off the main circuit 
breaker or by removing the fuse from the consumer unit.

•  Ensure that there are no electrical wires or water pipes behind the ceiling 

panel where you intend to drill the mounting hole.

•  The product is intended for flush fitting ceiling installation.
•  The product is intended for indoor use only (IP20).
•  Min 20 cm distance from the light source to the closest surface.
•  Do not touch the light fitting when it is on or before it has cooled 

adequately after being shut off.

•  Avoid looking directly into the light source when it is on.
•  The light source cannot be replaced. The product should be discarded 

once it has reached the end of its service life.

•  The light source is not dimmable.

Product description

•  LED downlight for fixed installation.
•  Comes with one white and one silver 

accent ring.

•  Tiltable lamp body.

Installation

Preparations

• 

This product must only be installed by a qualified 
electrician.

•  Disconnect the power to the circuit you are working 

on, either by turning off the main circuit breaker or by 
removing the fuse from the consumer unit.

•  Ensure that there are no electrical wires or water 

pipes behind the ceiling panel where you intend to 
drill the mounting hole.

•  Avoid covering the back of the light fitting with any 

heat insulating material.

Note:

The distance between the ceiling panel and 
any material present behind it must be at least 
50 mm in order for the lamp housing to reach 
its full tilting positions.

Drill a hole into the ceiling 
panel with a 68 mm diam 
hole saw.

Connection

1.  Cut the incoming mains power wires to a length that allows:

 

- The lamp to be rotated about 90º in its mounting hole.

 

- The lamp housing to be tilted to its full extent in all possible directions.

2.  Hold the lamp directly under the mounting hole while connecting 

the power wires to the terminal block.

Mounting

1.  Twist the lamp into its desired position (consider how you want to tilt 

the lamp housing to point the light to where you want it).

2.  Pull the spring clips back and insert the lamp into the mounting hole.
3.  Press the lamp upwards until the accent ring lies flush against 

the ceiling panel.

4.  Select the desired accent ring colour.
5.  If you wish to change the accent ring, turn it anti-

clockwise to remove it.

6.  Fit the accent ring’s mounting lugs into the lamp 

housing’s slots and turn clockwise to secure it.

7.  Turn on the mains. The light is now ready for use.

Instructions for use

•  Do not touch the light fitting when it is on or before it has cooled 

adequately after being shut off.

•  Tilt the lamp by pushing the edge of glass diffuser to the desired angle.

Care and maintenance

•  Turn the lamp off and let it cool.
•  Clean the product using a lightly moistened cloth. Use only mild cleaning 

agents, never solvents or corrosive chemicals.

•  Make sure that the light fitting is dry before turning it on.

Responsible disposal

This symbol indicates that this product should not be 
disposed of with general household waste. This applies 
throughout the entire EU. In order to prevent any harm to 
the environment or health hazards caused by incorrect waste 
disposal, the product must be handed in for recycling so that 
the material can be disposed of in a responsible manner. 
When recycling your product, take it to your local collection 
facility or contact the place of purchase. They will ensure that 
the product is disposed of in an environmentally sound manner.

Specifications

Rated voltage 

220–240 V AC, 50 Hz

Protection class 

IP20

LED light bulb 

4 W (not replaceable)

Lumens 

250 lm

Rated life 

15 000 hours

Outer diam (accent ring) 

86.3 mm

Depth

 41.4 mm

Mounting hole diam 

68 mm

Min mounting depth

 50 mm

Weight 

75 g

Summary of Contents for D10-023N0-027

Page 1: ... where you intend to drill the mounting hole Avoid covering the back of the light fitting with any heat insulating material Note The distance between the ceiling panel and any material present behind it must be at least 50 mm in order for the lamp housing to reach its full tilting positions Drill a hole into the ceiling panel with a 68 mm diam hole saw Connection 1 Cut the incoming mains power wir...

Page 2: ...taket Undvik att täcka armaturens bakstycke med värmeisolerande material Obs Avståndet från innertakets underkant till bakom liggande material måste vara minst 50 mm för att lamphuset ska kunna vinklas fullt ut Gör ett hål i innertaket med en Ø 68 mm hålsåg Anslutning 1 Kapa inkommande elkablar till en längd som tillåter att Lampan kan vridas ca 90º i monteringshålet Lamphuset kan vinklas mellan s...

Page 3: ...m at det ikke er strømledning eller vannrør i tak der du skal bore Unngå at armaturens bakstykke blir tildekket med varmeisolerende materiale Obs Avstanden fra himlingens underkant til bakom liggende materiale må være minst 50 mm for at lampehuset skal kunne vinkles fullt ut Lag et hull i himlingen med en Ø 68 mm hullsag Tilkobling 1 Kapp innkommende strømkabler til en lengde som tillater at Lampe...

Page 4: ... peitä valaisimen takaosaa lämmöneristävällä materiaalilla Huom Sisäkaton alareunan ja sen takana olevan materiaalin välisen etäisyyden tulee olla vähintään 50 mm jotta lampun voi kääntää Tee sisäkattoon Ø 68 mm n reikä Liittäminen 1 Lyhennä sisään tulevat johdot niin että Lamppua voi kiertää noin 90º asennusreiässä Lampun runkoa voi kääntää kaikkiin asentoihin 2 Pidä lamppua katossa olevan reiän ...

Page 5: ...icht mit wärmeisolierendem Material abdecken Hinweis Der Abstand von der Unterkante der Zimmerde cke zum dahinter liegenden Material muss mind 50 mm betragen damit das Lampengehäuse vollständig abgewinkelt werden kann Mit einer Lochsäge mit Ø 68 mm ein Loch in die Zimmerdecke sägen Anschluss 1 Zuführende Stromleitungen auf eine Länge kürzen die Folgendes ermöglicht Die Leuchte kann im Montageloch ...

Reviews: