BAT32G1x9 user manual | Chapter 34 Option bytes
1138 / 1149
Rev.1.02
34.3 The format of the flash data protection option bytes
The format of the flash data protection option bytes is as follows.
Figure 34-4 Flash Data Protection Option Bytes (000C3H).
Address: 000C3H
Symbol
7
6
5
4
3
2
1
0
OCD[7:0]
Address: 500004H
Symbol
7
6
5
4
3
2
1
0
OCDM[7:0]
OCDM
OCDEN
Control of flash data protection
3C
C3
Operations on flash data via debugger
are not
allowed.
Values other
than 3C
C3
C hip
full erase
of flash data
via d
ebugger
is allowed, read and write
operations are not allowed.
Except for the above note
Allows read/write/erase operations on flash data
via d
ebugger