CMP NOVA 25513-26 Series Instruction Manual Download Page 3

3

A. SAFETY INSTRUCTIONS & PRECAUTIONS

When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 

ft or they must be located on two different planes.

WARNING: DO NOT locate suction outlets on seating areas or on backrests for such seating areas.

Attention Installer: This manual contains important information about the installation, operation and safe use of this 

product. Before installing this product, read and follow all warning notices and instructions which are included. This 

information should be given to the owner and/or operator of this equipment.

To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in 

gallons per minute that exceeds the flow rate of your system by at least 25%.  Always use multiple suction outlets.  If 

the fitting/cover breaks, is damaged, or is missing, shut the system down immediately.  Do not use the system until 

damaged parts have been replaced.

Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times. Persons with long 

hair should secure hair to a minimal length or wear swimming cap.  Children should never be left unattended at any 

time in a swimming pool, spa, or bathtub.  Be sure the temperature of the water never exceeds the manufacturer’s 

recommendations.

To reduce the risk of injury, installation and service should be done by a qualified Service Professional, certified 

electrician or authorized CMP representative.

NOTE: In the event that one suction outlet is completely blocked, the remaining suction outlet(s) serving that system 

MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system.

Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or 

death.

All Suction Outlet Fitting Assemblies (SOFAs) shall be installed in accordance with the manufacturer’s installation 

instructions, or for Registered Design Professional SOFAs, in accordance with the registered design professional’s 

engineering plans. Field modification made to a SOFA not authorized by the manufacturer’s installation instructions 

shall void the SOFA certification.

Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting. 

Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against 

suction fittings. Never exceed the maximum allowable flow rate stated on the suction fitting. The suction fitting and 

fasteners should be inspected for damage or tampering before use. Missing, broken, or cracked suction fittings shall 

be replaced. Loose suction fittings shall be reattached or replaced before use of this facility.

The maximum hose length difference between any self-contained SOFA and the tee leading to the pump shall not 

exceed 13 feet (3.96 m).

CMP drain covers are only certified for use with CMP sumps and frames.  Do not mismatch with parts from other 

manufacturers.

When installing and using this equipment, basic safety precautions shall always be followed, including the following:

IMPORTANT SAFETY INSTRUCTIONS. 

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS.

 

ALWAYS PLUMB AND INSTALL ALL SUCTION FITTINGS ACCORDING TO ALL 

BUILDING CODES THAT APPLY IN YOUR AREA.

WARNING

WARNING

WARNING

WARNING

WARNING

NOTICE

NOTICE

NOTICE

NOTICE

NOTICE

NOTICE

NOTICE

SAVE THESE INSTRUCTIONS

Summary of Contents for NOVA 25513-26 Series

Page 1: ...uirements All Custom Molded Products main drains are listed and tested in strict accordance to the requirements of ANSI APSP 16 2017 the current standard of reference for the Virginia Graeme Baker Act...

Page 2: ...3 B Sizing Specification Reference 4 C Installation Maintenance Procedures 6 1 Required for Installation 6 2 Installation Location 6 3 Installation Procedure 6 4 Maintenance Inspection 8 5 Winterizin...

Page 3: ...MUST have a flow rating capable of the full flow of the pump s for the specific suction system Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapm...

Page 4: ...mbining the flow rating of all SOFAs minus the flow rating of one If the flow ratings of all SOFAs are not equal subtract the flow rating of the SOFA with the highest flow rating NOTICE No modificatio...

Page 5: ...0 100 120 140 160 180 200 0 079 3 22 0 72 0 20 1 97 TOTAL HEAD LOSS Feet of Head FLOW RATE 2 5in PIPE 0 0 2 0 2 0 4 0 6 0 8 1 1 4 1 2 0 50 100 150 200 250 03 1 45 0 38 0 18 0 88 TOTAL HEAD LOSS Feet o...

Page 6: ...tall in the center of the pool spa OR the deepest point b Cover grates when installed shall not protrude more than 2 in 51 mm from the finished surface of the pool in which the SOFA is installed c See...

Page 7: ...eners The use of adhesives or other attachment methods that prevent access to suction piping or SOFA components requiring periodic servicing is prohibited Hand check cover grate for snugness to the su...

Page 8: ...replacement is made e If there are stripped screw holes or if the brass insert receptacles are missing removed the SOFA must be replaced Do not use the pool spa facility until a repair or replacement...

Page 9: ...RAMS AND MEASUREMENTS IMAGE 2 DIMENSIONS NOVA SIDE VIEW LARGE OUTLET NOVA SIDE VIEW A LARGE OUTLET NOVA SIDE VIEW B NOVA BOTTOM VIEW 3 6 8 8 5 8 5 3 75 4 2 6 6 3 8 1 4 7 5 4 9 10 1 8 7 8 5 8 0 3 3 0 9...

Page 10: ...5515 1 61050 048 025 SCREWS FOR 25517 2 25539 700 011 COVER 3 25513 250 020 PLUG FOR 25513 26X 25516 26X 3 25513 300 020 PLUG FOR 25513 4XX 25516 4XX 3 25520 050 010 PLUG FOR 25513 5XX 25516 5XX 4 255...

Page 11: ...___________________________________________ Installation Date _____________________________ Model Number ______________________________ Pool Size in Gallons __________________________ CMP Customer Ser...

Page 12: ...CUSTOM MOLDED PRODUCTS 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM 0521sb...