mDT001 HazMon System Tester Technical Manual /9
CMC INDUSTRIAL ELECTRONICS LTD
Phone: (604) 421-4425 Toll Free: (888) 421-4425
Fax: (604) 421-7734
www.cmciel.com [email protected]
The Industry Leader
in HazMon Technology
The following table lists the allowable tolerance set for each of the sensors permitted on the CMC
network:
Model
Family
Code
Ground
Fault
Data
Maximum
Ground
Fault
Power
Maximum
Ground
Fault
Common
Maximum
Power
Supply
Minimum
Data
Low
Maxi
mum
Data
High
Maximum
mTS01X
40
0.25
0.25
0.25
4.75
0.25
3.85
mRS001
160
0.25
0.25
0.25
4.58
0.25
3.75
mVM001
161
0.25
0.25
0.25
4.58
0.25
3.75
mCM001
162
0.25
0.25
0.25
4.61
0.25
3.75
mRH001
163
0.25
0.25
0.25
4.66
0.25
3.75
mDI001
165
0.25
0.25
0.25
4.63
0.25
3.75
mTS017
166
0.25
0.25
0.25
4.67
0.25
3.75
mTC001
177
0.25
0.25
0.25
4.47
0.25
3.85
mAM001
178
0.25
0.25
0.25
4.61
0.25
3.75
mTC002
179
0.25
0.25
0.25
4.18
0.25
3.85