background image

11-2016

EST-VENTLESS 3-DOOR

FRONT VIEW

WARNING

: Electrical and plumbing connections need to be 

made by a licensed service person and comply with all Federal, 
State and Local Health, Electrical, Plumbing and Safety codes.

EST Ventless 3 Doors

Quick Setup Instructions

STEP

6

Open dishmachine doors completely. Closing the doors 

will automatically activate the machine and Door

Safety Interlock will lock the doors until machine cycle

is complete.

7

STEP

Adjust the temperature by removing the panel in front 

of the respective heater and turning the adjustment 

post. Wash temp. 120°F./140°F. 

OFF ON

FILL

START

-

ENERGY SAVER

EST

 

 

-

ENERGY SAVER

EST

 

 

STEP

5

Immediately after power is turned on,

 press 

FILL switch to fill the booster heater. When the water 

begins to flow into the cabinet, connect the two wires

(see step 5 for booster connection). Wait for 5 minutes

to allow booster heater to reach temperature. Press 

FILL switch again to fill the wash tank.

 

BLACK/YELLOW

STRIPED WIRE

BOOSTER HEATER 

DAMAGE PREVENTION

CAUTION

: TO PREVENT BOOSTER HEATER ELEMENT 

DAMAGE,  CMA HAS DISCONNECTED A WIRE FROM 
THE “THERMOSTAT”.  THE BOOSTER TANK 

MUST 

BE FILLED WITH WATER PRIOR TO CONNECTING THE 
“REMOVED”WIRE,  AT THE INITIAL FILLING OF A 
NEWLY INSTALLED DISHMACHINE.  THE BOOSTER 
TANK INDICATES FULL  WHEN YOU CAN OBSERVE 
WATER INSIDE THE MACHINE.  AT THIS POINT,  AND 
ONLY AT THIS POINT,  SHOULD YOU CONNECT THE 
“DISCONNECTED” WIRE.  

FAILING TO FOLLOW 

THESE IMPORTANT INSTRUCTIONS WILL DESTROY 
THE HEATING ELEMENT,  BECAUSE THE ELEMENT 
SHOULD ONLY OPERATE WHEN FULLY SUBMERGED 
IN WATER.

 

OFF ON

FILL

START

-

ENERGY SAVER

EST

 

 

-

ENERGY SAVER

EST

 

 

4

STEP

Press "POWER ON/OFF" rocker switch to turn on 

dishmachine. After machine is turned off, the 

condenser wash will activate automatically. 

OFF ON

FILL

START

-

ENERGY SAVER

EST

 

 

-

ENERGY SAVER

EST

 

 

VENTLESS  

VENTLESS

The Spirit of Excellence

an Ali Group Company

RINSE

CHEMICAL 

PUMPS

ON  OFF SWITCH

FILL START 

SWITCH

DETERGENT SANI

PRIMER

TEMPERATURE

GAUGE

5

4

DRAIN

COLD WATER

INLET

DOOR LOCK

DOOR

HANDLE

6

BOOSTER HEATER

CONNECTION

5

HEATER

CONTACTOR

 BOOSTER 

HEATER

THERMOSTAT

7

PN: 10130.25

Reviews: