Note:
If at any time less than a full Auto Fill cycle is desired with the IDEC brand
timer, the Auto-Fill can be interrupted (stopped) by turning off the power to the
machine. The machine will resume normal operation upon restoring power without
continuing the Auto Fill cycle.
3.1.3. Rinse Pressure Regulator
The CMA-66 requires a supply water pressure of 24 PSI minimum. The pressure is
then reduced by the supply water regulator. Use the following procedure to adjust
the rinse pressure to 20 PSI:
1. Close the door on the machine.
2. Turn the Power switch to the "ON" position.
3. Using a rod or something long to avoid contact with the rinse water, actuate
the final rinse trip switch—this activates the water solenoid. With the rinse
water flowing adjust the pressure regulator until the gauge reads 20 PSI.
Adjustment tip:
Always adjust “down” when setting this pressure regulator. In
other words—intentionally raise the pressure above the desired set point and
then carefully bring it down to the correct pressure.
3.1.4. Wash Tank Temperature
The wash tank temperature for the CMA-66 is set at the factory. Should you ever
find a need to adjust it—after replacement of the thermostat for example—simply
perform steps 1 through 4 in section
3.2 Beginning Operation.
MODEL CMA-66 Installation & Operation Manual Rev. 1.09 B
Page
15
Summary of Contents for CMA-66 L.T.