![CMA Dishmachines CMA-180VL Service And Parts Manual Download Page 16](http://html.mh-extra.com/html/cma-dishmachines/cma-180vl/cma-180vl_service-and-parts-manual_2627040016.webp)
MODEL CMA-180VL Service & Parts Manual Rev. 2.01
Page
17
4. Quick Service Guide
MODEL: CMA 180 VL HIGH TEMP
TECHNICAL ISSUE
CAUSE
SOLUTION
Door magnetic reed switch problem Faulty magnetic reed switch
Check wire connections inside control box
Contact factory for new retrofit, corner straight
Door mechanical switch problem
Switch alignment issue
Align switch
Switch button broke
Replace switch
Delimer switch is in
OFF position
Flip to
NORMAL position
Loose wire connections
Check and crimp connectors
Pump motor not running
Faulty # 3 micro switch in cam timer
Replace micro switch
Faulty contactor
Replace contactor
Faulty wash pump motor
Replace wash pump motor
Faulty # 3 micro switch in cam timer
Replace micro switch
Pump motor runs continuous
Delimer switch is in
DELIME position
Flip to
NORMAL position
Faulty contactor
Replace contactor
Booster heater thermostat not properly set
Adjust thermostat
Incoming main water temperature below 140 F Raise water temperature to 140 F
Final rinse water below 180 degree F
Tripped or faulty high limit switch
Reset or replace high limit switch
Faulty contactor
Replace contactor
Faulty booster heater element
Replace heating element
Scaled heating element
De- scale heating element
Thermostat is not properly adjusted
Adjust thermostat
Loose lead connection
Check connectors and secure
Wash tank heater is not operational Tripped or faulty high limit switch
Reset or replace high limit switch
Faulty float switch
Replace float switch
Faulty contactor
Replace contactor
Faulty heating element
Replace heating element
Water regulator not adjusted properly
Adjust regulator to 18-20 PSI
Clogged final rinse spray jets
Clean jets
Low water pressure at the final rinse Missing final rinse spray end cap
Replace end cap
Low incoming water pressure from building
Increase pressure
Water solenoid leaks
Scaled or dirty solenoid valve
Clean valve
Faulty solenoid valve diaphragm
Replace diaphragm
Thermostat not properly set
Adjust thermostat
Wash water temperature too low/high Scaled heating element
Clean scale, delime machine
Faulty temperature gauge
Replace gauge
Position or proper operation of door switch
Adjust or replace door switch
Delimer switch is on
OFF position
Flip to
NORMAL position
Faulty 1st micro switch in cam timer
Replace micro switch
Machine does not operate when the
door is closed
Check cam timer motor
Replace timer if needed
Check ice cube relay
Replace if faulty
Faulty wash pump contactor
Replace contactor