Getting Started 

 

2.2.3.  Connecting the Scrap Accumulator and Drain 

The scrap accumulator is designed to perform two basic functions: 

1.  It allows all the heavy solids to discharge out of the machine with each wash cycle and 

collect in a clean out tray. 

2.  It provides accumulation capacity to allow draining the contents of one cycle regardless 

of the discharge rate of the existing drain. 

The drain pipe is connected to the scrap accumulator drain using a 2” no-hub connector (not 
supplied) as shown in 

Figure 2.2.3

 

below. 

 

 

 

Figure 2.2.3

 

2.2.4. Installer’s 

Checklist 

 

 

Dishmachine checked for concealed damage 

 

Hot water supply is minimum 120°F, recommended 140° F (49/60 C) 

 

Incoming water supply line is ¾” minimum (not galvanized) 

 

Supply circuit breaker for machine is properly sized 

 

Service voltage and phase type are correct to machine data plate 

 

Drain pipe is installed with adequate air gap (must meet local codes) 

 

Dishmachine is properly grounded 

 

Dishmachine is properly leveled 

 

Machine circuit breaker is labeled  “DISHWASHER” 

 

Machine has been connected with correctly sized wire

 

MODEL AH, B & C INSTALLATION & OPERATION MANUAL Rev. 1.00A 

Page

 

9

Summary of Contents for AH/B/C/S

Page 1: ...l Keep with machine for reference MODELS AH B C S INSTALLATION OPERATION Rev 1 00 A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE CALIFORNIA 92841 8 0 0 8 5 4 6 4 1 7 FAX...

Page 2: ...D INSTALLATION 8 2 2 1 Electrical 8 2 2 2 Plumbing 8 2 2 3 Connecting the Scrap Accumulator and Drain 9 2 2 4 Installer s Checklist 9 3 OPERATION 10 3 1 INITIAL SETUP 10 3 1 1 Check 10 3 1 2 Filling t...

Page 3: ...ated 40 40 WASH TANK CAPACITY 1 7 GAL 6 45 L PUMP CAPACITY 52 GPM 197 LPM WATER REQUIREMENTS REQUIRED MINIMUM TEMP 120 F 49 C RECOMMENDED TEMP 140 F 60 C WATER INLET 1 9cm DRAIN CONNECTION 2 5 1cm DIM...

Page 4: ...80 80 WASH TANK CAPACITY 3 0 GAL 11 4 L PUMP CAPACITY two pumps 104 GPM 393 68 LPM WATER REQUIREMENTS REQUIRED MINIMUM TEMP 120 F 49 C RECOMMENDED TEMP 140 F 60 C WATER INLET 1 9cm DRAIN CONNECTION 2...

Page 5: ...n a couple of seconds cams 1 and 2 close their respective switches Cam switch 1 Start Stop maintains power to the timer assembly motor throughout the 90 second cycle Cam switch 2 Cycle Reset energizes...

Page 6: ...ump motor restarts carrying out the rinse portion of the cycle as the filling of the wash tank completes This can be adjusted as necessary for water pressure situation 5 Cam switch 5 controls the dete...

Page 7: ...tructured to provide a complete reference guide to the models AH B C S series Dishmachines It is presented in a manner that all users will be able to comprehend and use as an effective tool in support...

Page 8: ...for rinse aid 2 2 1 Electrical A 20 amp 115 volt 60 Hz dedicated circuit must be used to supply electrical power to the model AH and model C Dishmachines see model AH specifications on page 3 and mode...

Page 9: ...connector not supplied as shown in Figure 2 2 3 below Figure 2 2 3 2 2 4 Installer s Checklist Dishmachine checked for concealed damage Hot water supply is minimum 120 F recommended 140 F 49 60 C Inco...

Page 10: ...ERATION MANUAL Rev 1 00A Page 10 a Red detergent line b Blue rinse agent line c Clear White sanitizer line Activate the prime switches for the three chemical pumps until product is discharging into th...

Page 11: ...oors The machine will automatically start when the doors are closed 8 After the machine stops raise the doors remove the rack of dishes allow to dry before stacking 9 Insert the next rack of dishes in...

Page 12: ...n Dishwashing machines shall be thoroughly cleaned at least once each day The pumps and the wash and rinse sprays or jets shall be so designed that a forceful stream of water will reach all surfaces o...

Page 13: ...3 4 Electrical Diagrams 3 4 1 Models AH C B MODEL AH B C INSTALLATION OPERATION MANUAL Rev 1 00A Page 13...

Page 14: ...3 4 2 Solid Bowl MODEL AH B C INSTALLATION OPERATION MANUAL Rev 1 00A Page 14...

Reviews: