GASOLINE VEHICLE - TROUBLESHOOTING
AND ELECTRICAL SYSTEM
Test Procedures
18
TEST PROCEDURE 9 – Maintenance/Operate Switch – Pedal-Start Vehicles
See General Warnings on page 1-2.
NOTE:
This is a continuity test.
The Maintenance/Operate Switch is also known as the Neutral Lockout Switch.
1.
If necessary, see Testing Basics on page 18-10.
2.
Remove wires from switch
3.
With switch in position 1 (MAINTENANCE):
3.1.
Check for no continuity between terminals T1 and T2.
3.2.
Check for continuity between terminals T2 and T3.
4.
With switch in position 2 (OPERATE):
4.1.
Check for no continuity between terminals T2 and T3.
4.2.
Check for continuity between terminals T1 and T2.
T1
T3
T2
2
1
1. Position 1 (MAINT.)
closes T2 to T3
Toggle Position Operates:
2. Position 2 (OP.) closes
T1 to T2
3. T1 – Black/Light Blue Stripe, T2 – Black, T3 – Black/Yellow Stripe
478
Figure 18-6
Maintenance/Operate Switch Test – for
Pedal-Start Vehicles
5.
If switch:
5.1.
does not work as stated in previous steps, replace switch.
5.2.
does work as stated and the MAINTENANCE/OPERATE modes still do not work:
– Check the limit switches.
– Check continuity of the wires involved.
2019 Precedent Villager 2 Maintenance and Service Manual
Page 18-23
Summary of Contents for Precedent Villager 2
Page 2: ......
Page 395: ...ELECTRIC MAIN HARNESS Wiring Diagrams Electric Main Harness 25...
Page 396: ...Page intentionally left blank...
Page 398: ...Page intentionally left blank...
Page 399: ...GASOLINE MAIN HARNESS Wiring Diagrams Gasoline Main Harness 25...
Page 400: ...Page intentionally left blank...
Page 402: ...Page intentionally left blank...
Page 403: ...GASOLINE ENGINE HARNESS Wiring Diagrams Gasoline Engine Harness 25...
Page 404: ...Page intentionally left blank...
Page 412: ...NOTES...
Page 413: ......
Page 414: ......