CLS FOCUS COMPACT SPOT GII Manual Download Page 3

www.cls-led.com

www.cls-led.com

6

5

EXTENSION PIPE

1

2

3

4

5

6

7

8

Loosen

Max. 10 x extension pipe 10 cm on 1 Focus!
Max. 4 x extension pipe 30 cm on 1 Focus!

Secure

Set the Focus in 

the desired 

direction

1

2

3

4

5

6

7

8

Loosen

Max. 10 x extension pipe 10 cm on 1 Focus!
Max. 4 x extension pipe 30 cm on 1 Focus!

Secure

Set the Focus in 

the desired 

direction

Summary of Contents for FOCUS COMPACT SPOT GII

Page 1: ...install genuine parts on this product Qualified technician Make sure all connectors are connected properly Always switch off mains power of the driver before connecting or maintaining any fixtures Wall Ceiling 360º Floor 90º 150 cm 50 000 h 135 gr 1 x Cree Luxeon IP20 Max 700mA Max 3 Watt 3000K CRI 85 3000K CRI 95 4000K CRI 85 1 10 V dimmable Phase dimmable DALI dimmable 2700K CRI 85 2700K CRI 95 ...

Page 2: ...upler 90º End piece 90º 24 mm Ø 36 mm 24 mm Tools 1 5 TECHNICAL SPECIFICATIONS LED 1 x Luxeon Cree Available colours CRI 85 2700K 3000K 4000K CRI 95 2700K 3000K Beam angle 13º to 65º Power supply Max 700mA Power consumption Max 3 Watt Housing Black Aluminum brushed White coated Weight 135 gr IP value IP20 Cable length 150 centimeter Measurements ø 36 x 85 mm øxh Ambient temperature 10º C till 40º ...

Page 3: ...ION PIPE 1 2 3 4 5 6 Loosen Max 10 x extension pipe 10 cm on 1 Focus Max 4 x extension pipe 30 cm on 1 Focus 5 6 7 8 Max 10 x extension pipe 10 cm on 1 Focus Max 4 x extension pipe 30 cm on 1 Focus Secure Set the Focus in the desired direction ...

Page 4: ...005 B CLS Focus Coupler Black 90º Y106005 W CLS Focus Coupler White 90º 1 1 2 A B C 2 3 Secure 1 2 3 Treath the cables trough the extension pipe by starting at A then B and final C 5 6 7 8 Max 2 x couplers and 1 End piece on a Focus Tree Max total length is 120 cm Secure 1 2 3 Secure 1 2 3 Treath the cables trough the extension pipe by starting at A then B and final C Set the Focus Tree in the des...

Page 5: ...ble 120 180 cm cable 129 5 mm 42 mm CLS Focus Compact Spot GII FC X X XX Z Always switch off mains power of the driver before connecting any fixtures Always switch off mains power of the driver before connecting any fixtures CLS ND 008 150 cm cable Installation wire 2 x 0 5 mm2 Driver till last Focus Compact GII total cable length is max 10 m CLS ND 008 non dimmable 500 1050mA driver 30 x 129 5 x ...

Page 6: ...S Focus Compact Spot GII FC X X XX Z Always switch off mains power of the driver before connecting any fixtures WIRING DIAGRAM 1 10V DIM DRIVERS Installation wire 2 x 0 5 mm2 Driver till last Focus Compact GII total cable length is max 10 m CLS VD 001 1 10V dimmable 350 900mA driver 22 x 100 x 52 mm hxwxd CLS VD 001 0 10 V 80 5 mm w 80 5 mm h CLS Dimmer electr 1 10V 872010 L N 120 180 cm cable 150...

Page 7: ...2 Driver till last Focus Compact GII total cable length is max 10 m CLS DD 001 DALI dimmable 250 700mA driver 22 x 100 x 52 mm hxwxd CLS DD 001 120 180 cm cable 120 180 cm cable 150 cm cable Always use 1 8 pcs of Focus Compact GII on the CLS DD 001 DA1 DA2 Controller Supporting DALI CLS Focus Compact Spot GII FC X X XX Z CLS SmartConnect 6 fold junction box 87129905 52 mm 100 mm Installation wire ...

Page 8: ...Connect 6 fold junction box 87129905 24 VDC powersupply Min 2 and max 6 pcs on each channel 48 VDC powersupply Min 7 and max 12 pcs on each channel Also select the correct BT powersupply according to the consumed power Always switch off mains power of the driver before connecting any fixtures ZOOM FUNCTION 1 1 2 2 Twist system Pull Push system Applied on the black Focus Applied on the white Focus ...

Page 9: ...Information subject to change w ithout notice CLS LED BV and all affiliated companies disclaim liability for injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual No part of this manual may be reproduced in any form or by any means w ithout permission in writing from C...