1

 

CDS552 CIRRUS LOOP LOGGER 

1.1

 

Introduction 

 
The  Cirrus  Loop  logger  is  a  robust,  sophisticated  LTE/4G  GSM  logger/controller  with  a  wide  range  of  input  capabilities, 
making it ideal for a large number of measurement applications. 
 
Communication to your own server and database can be achieved via the internet or a private APN. The software running 
on  these  servers  is  supplied  free  of  charge.  The  Cirrus  Loop  Logger  has  been  designed  to  allow  for  easy  installation  and 
setup  without  the  need  for  a  complicated  server  infrastructure.  Setup  and  management  software  (CloudWorks)  is  also 
supplied  free  of  charge  to  allow  clients  to  manage  their  own  networks  and  data.  There  are  no  monthly  charges  for 
collecting and hosting data as the client can provide this service themselves. 

 
 

1.2

 

Features 

 

 

Uses  GPRS/EDGE/LTE/4G  technology.  4G  has  become  essential  as  many  cellular  network  providers  around  the 
world will soon no longer be supporting older GPRS/3G technologies, rendering these legacy dataloggers obsolete. 
This has already started happening in many countries around the world. 

 

Bluetooth interface - setup and manual data collection can be achieved through the Bluetooth interface negating 
the need for cables that invariable fail during continuous use.  

 

Optional external power operation with battery failover.  

 

Uses standard off-the-shelf alkaline batteries. This logger uses 3x standard D Cell alkaline batteries that can last in 
excess of 5 years under normal usage. Many other loggers use lithium batteries that are expensive and difficult to 
obtain. Other problems involving  lithium batteries are the restrictions when shipping using airfreight. All  lithium 
batteries need to be shipped as hazardous cargo that is becoming increasingly difficult to achieve as many airlines 
are no longer allowing these batteries on their aircraft.  

 

2  x  Pulse  input  ports  -  Pulse  inputs  are  used  on  metering  devices  that  supply  a  pulse  output  for  a  measured 
amount of product. 

 

Isolated 4-20mA interface. Used for any sensing device with a 4-20mA output.  

Summary of Contents for CDS552

Page 1: ...ital Solutions This document contains information relating to the rights of Cape Digital Solutions The confidentiality agreement provisions are applicable to this document When no longer needed for au...

Page 2: ...LOOP LOGGER DOCUMENT NAME CLASSIFICATION DATE PAGE CDS552 CIRRUS LOOP LOGGER USER MANUAL CONFIDENTIAL 15 JUL 21 2 OF 29 AMENDMENT HISTORY Issue Date Amendment Details Amended By V01 13 July 2021 Comp...

Page 3: ...button functions 7 1 6 1 LED functions 7 1 6 2 Pushbutton Functions 7 1 7 Connections 8 1 7 1 External Power Supply Solar System Connection 9 1 7 2 Using the 4 20mA loop input and 24V loop power gener...

Page 4: ...al as many cellular network providers around the world will soon no longer be supporting older GPRS 3G technologies rendering these legacy dataloggers obsolete This has already started happening in ma...

Page 5: ...gth network status etc Touch sensitive button and LED s for manual wakeup to server and diagnostic purposes etc 1 3 Specifications GPRS EDGE LTE 4G Modem Technology LTE FDD B1 B3 B5 B7 B8 B20 B28 LTE...

Page 6: ...ries that will last several years depending on the operation In this mode the logger will wakeup adjustable normally 6 hourly and upload its recorded data to a remote database External 12V 8 15V 2A su...

Page 7: ...ion has been established to the server 1 6 2 Pushbutton Functions SELECT touch button Please note this button is touch sensitive in order to maintain the waterproof status of the housing Single short...

Page 8: ...on has been pressed Once the Red Status LED comes on again the button can be released This will now reset the Bluetooth interface 1 7 Connections Connections are available on a series of 10 terminal c...

Page 9: ...into dual mode In this mode while there is solar power available the logger will remain online with the server Should the solar power fail the logger will automatically switch to battery mode until t...

Page 10: ...en designed to supply a maximum of 30mA Please note using the 24V power generator to power a loop device uses a substantial amount of power For this reason in battery operated devices the loop should...

Page 11: ...AME CLASSIFICATION DATE PAGE CDS552 CIRRUS LOOP LOGGER USER MANUAL CONFIDENTIAL 15 JUL 21 11 OF 29 Example configuration of water meter with electronic interface Please note the polarity of the interf...

Page 12: ...he CDS552 Cirrus logger uses a MicroSIM and is installed as follows 1 Slide the cover plate backwards to unlock 2 Flip the cover plate up to expose the connections 3 Place the sim card with the connec...

Page 13: ...9 Installation considerations The CDS552 Cirrus Loop logger is environmentally rated to IP68 max1 2m In order to achieve this it is critical that any cables entering the logger are properly sealed by...

Page 14: ...ers that sleep most of the time 2 1 Setup via Bluetooth Configure The CDS552 Cirrus Loop logger has an onboard Bluetooth interface which allows for the device configuration to be done locally There ar...

Page 15: ...e devices in the immediate vicinity Once the search has been completed a list of all the available devices will be displayed Should the device you are looking for not appear in the list press the Refr...

Page 16: ...ach device type This device will immediately be placed into Command Mode and the current setup data retrieved and displayed on the right hand screen Data update commands are sent to the device only af...

Page 17: ...de before any of the settings changes or other instructions are accepted Sending a command in Diagnostic Mode will cause the logger to switch to Command Mode but that last instruction will fail The in...

Page 18: ...nt power status of the logger Battery or Mains Current 4 20mA loop current reading in milliamps The 4 20mA current loop reading with its calibration data implemented including the unit of measure The...

Page 19: ...Vendor Code The Cloudworks System supports multiple databases What this means is that the server will automatically populate the database that is associated with a specific logger Each database and lo...

Page 20: ...a note it is always better to rather use the IP address than the domain name This will mean that the logger will not have to execute a domain name lookup before connecting to your server Cloudworks l...

Page 21: ...le serial numbers separated by a comma for instance Any data that is useful could be stored here The Engineering box contains parameters involved with the setup of onboard functions of the logger The...

Page 22: ...reshold voltage This should only under special circumstances be adjusted from 4 75V Fitted onto each logger is an onboard 24V 30mA power generator The Cumulus Logger can generate a stable 24V output a...

Page 23: ...server This will also force a battery logger to connect to the server Applies only to battery loggers and will force the logger to sleep rather than connect to the server Dropdown menu giving to opti...

Page 24: ...Current 8 Disconnect loop current Upgrading firmware on the logger can be done through the Bluetooth interface Newer versions of the software for each type of device is embedded into the Cloudworks s...

Page 25: ...itors discharge enough for the device to reset To speed this process up press the pushbutton for more than 3 seconds forcing the device to try and connect to the server and therefore draining the capa...

Page 26: ...evice only after the parameter setup field has been left What this means is that while adjusting a parameter in its input box no commands are sent to the logger Once you have completed entering the fi...

Page 27: ...e screen has one further tool available in its arsenal and that is the Send Test SMS function The purpose of this function is to not only test the SMS system but also to determine the telephone number...

Page 28: ...pty at this point To create a script simply enter the new values for the parameters you wish to change in the correct fields The script will only be generated for the parameters that have been altered...

Page 29: ...rmine its status at any point by pressing the Read Script button Clear Script would delete the script from the database All the other functions should be familiar with the exception of the Clear Datal...

Reviews: