BT-1 Installation Guide v1.0
7
Installation - connections
Connection to a Facility Port (BT-1F only)
The BT-1 has two PCBs “piggy-backed” onto the rear of the faceplate. The RJ45 output connector (SK1) is located on the upper
PCB:
LOCATION OF REAR RJ45 CONNECTOR
(Sketch simplified; only primary components shown)
RJ45 OUTPUT
CONNECTOR
INSERT PLUG THIS
WAY, LATCH UPWARDS
SK1
RSL-6
3 2 1
The output connector should be connected to the host unit’s
FACILITY PORT
for the Zone in which it is installed* with
screened
Cat 5 cable and shielded RJ45 plugs.
Connect to SK1
Screened
Cat 5 cable
HOST UNIT (Z8
MK4
illustrated)
100 m max
Connect to
FACILITY PORT
BT-1
(UK version illustrated)
The maximum total Cat 5 cable length should not exceed 100 m. If further modules are being “linked” together (see
“Connecting
a BT-1F to an LM-2” on page 10
), this figure applies to the overall cable run from the host unit to the farthest module in the
chain.