CLOROX CLX1000 Operator'S Manual Download Page 8

8 |

5.  After spraying, keep the area closed to the public based  

on product SDSs.

6.  Remove the closed sign from the door once the reentry time  

has expired.

 
Changing Clorox-Approved Products

1.  Stop spraying the Clorox Total 360™ Electrostatic Sprayer.

2.  Disconnect the bottle connection from the Clorox-approved 

product that is to be changed and remove from the sprayer.  
Cap the removed product if it is being stored.

3.  Purging the Clorox Total 360™ Electrostatic Sprayer: Depress into 

an inconspicuous corner, container or drain. Spray the Clorox Total 
360™ Electrostatic Sprayer for about 20 seconds to purge the system.

4.  Chose the appropriate Clorox-approved product for cleaning, 

sanitizing or disinfecting.

5.  Mount desired Clorox-approved product on Clorox Total 360™ 

Electrostatic Sprayer base and strap into place. Ensure that the 
bottles are positioned with the opening facing up and the opening 
facing the dispensing tubes.

6.  Unscrew the lid on the Clorox-approved products of your 

choice and connect the Clorox Total 360™ Electrostatic Sprayer 
dispensing cap to the bottle. Be sure the cap is screwed all the way 
down, do not overtighten.

7.  Priming the Clorox Total 360™ Electrostatic Sprayer: Depress into 

an inconspicuous corner, container or drain. Spray the Clorox Total 
360™ Electrostatic Sprayer for about 20 seconds to generate a 
steady flow of solution. 

 
After Use and Storage

1.  Stop spraying the Clorox Total 360™ Electrostatic Sprayer.

2.  Disconnect the bottle connection from the Clorox-approved 

product that is to be changed and remove from the sprayer. Cap 
the removed product if it is being stored.

3.  Purging the Clorox Total 360™ Electrostatic Sprayer: Depress into 

an inconspicuous corner, container or drain. Spray the Clorox Total 
360™ Electrostatic Sprayer for about 20 seconds to purge the system.

4.  Turn off the unit. Blue indicator light on the instrument panel and 

base of the unit should no longer be illuminated.

5.  Unplug the Clorox Total 360™ Electrostatic Sprayer from wall.

6.  Wrap cord on cord holder on the Clorox Total 360 base unit.

8.  Store in a safe, dry place.

Preparing the Spray Area

1.  Clean gross filth by using standard manual cleaning protocols. 

2.  Close the room to the general public for cleaning. Place signs  

or warning indicators on doors that indicate no one should enter 
the room.

3.  Power off any sensitive electrical devices but do not unplug them.

 
Unit Operation/Setup

1.  Choose the appropriate Clorox-approved product for cleaning, 

sanitizing or disinfecting. 

2.  Mount desired Clorox-approved product on Clorox Total 360™ 

Electrostatic Sprayer base and strap into place. Ensure that the 
bottles are positioned with the opening facing up and the opening 
facing the dispensing tubes.

3.  Unscrew the lid on the Clorox-approved product of your choice and 

connect the Clorox Total 360™ Electrostatic Sprayer dispensing 
cap to the bottle. Be sure the cap is screwed all the way down,  
do not overtighten.

4.  Unwrap electrical cord completely and plug Clorox Total 360™ 

Electrostatic Sprayer into a grounded, three-pronged socket.

5.  Locate the On/Off switch on the base unit. Push the Total 360 

Sprayer to the “On” position. A blue light will illuminate on both 
the sprayer instrument panel and unit power switch.

6.  Put on appropriate personal protective equipment. See section  

on personal protective equipment on page 5.

7.  Remove the sprayer from the unit. A blue power indicator light 

should be illuminated on the sprayer.

8.  The system is now ready for use.

9.  Priming the Clorox Total 360™ Electrostatic Sprayer: Depress into 

an inconspicuous corner, container or drain. Spray the Clorox Total 
360™ Electrostatic Sprayer for about 20 seconds to generate a 
steady flow of solution. 

10  When spraying, a second blue indicator light will illuminate on the 

sprayer instrument panel when the trigger is depressed. 

NOTE: Sprayer will automatically stay on until trigger  
is depressed an additional time.

 
Sprayer Operation During Cleaning

1.  Position Clorox Total 360™ Electrostatic Sprayer in a rear corner  

of the area.

2.  Direct the nozzle at the desired surface. 

3.  Begin to spray. Press the sprayer button once to initiate spraying. 

Press once to stop flow of the sprayer. 

4.  Follow a continuous path around the area working from high to low 

areas moving the sprayer in a sweeping motion until surfaces are 
thoroughly wet. 

OPERATING INSTRUCTIONS

Summary of Contents for CLX1000

Page 1: ...static Sprayer CLX1000 115VAC 60Hz 7 0 A Indoor Commercial Use Only Operator s Manual 2016 The Clorox Company Professional Products Division 1221 Broadway Oakland CA 94612 1 800 492 9729 www cloroxtot...

Page 2: ...ls 6 SYSTEM COMPONENTS Clorox Total 360 Base Unit 7 Clorox Total 360 Sprayer 7 Nozzle 7 OPERATING INSTRUCTIONS Preparing the Spray Area 8 Unit Operation Setup 8 Sprayer Operation During Cleaning 8 Cha...

Page 3: ...e used by untrained personnel WARNINGS PRESSURIZED EQUIPMENT HAZARD Fluid from equipment that leaks or ruptures from a component can splash in the eyes or on skin causing serious injury In order help...

Page 4: ...n only be used with products that have been approved by Clorox Never spray any liquid product that is not a Clorox approved product The Clorox Total 360 Electrostatic Sprayer warranty is voided if the...

Page 5: ...In the event of malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipm...

Page 6: ...ker is provided on the rear of the unit It will trip if the unit experiences an electrical short 14 Always turn off sprayer after each application and before unplugging 15 Always unplug unit from outl...

Page 7: ...Air Filter User replaceable air filter that filters out particles from incoming air 5 Sprayer Holster Holds the sprayer 6 Adjustable Handle Handle position is raised lowered and rotated by the two bu...

Page 8: ...ry place Preparing the Spray Area 1 Clean gross filth by using standard manual cleaning protocols 2 Close the room to the general public for cleaning Place signs or warning indicators on doors that in...

Page 9: ...ooth spring return If any issues are noted remove replace immediately This is done by gently pulling on the spring loaded contact with a pair of pliers Otherwise service the spring loaded contact by a...

Page 10: ...ly or won t run while depressing the sprayer trigger This is a sign that the unit s circuit breaker has tripped or that the compressor has overheated The user should look to see if the white button wi...

Page 11: ...imer of Implied Warranties and Consequential Damages The Clorox obligation under this warranty to the extent allowed by law is in lieu of all warranties implied or expressed including implied warranti...

Page 12: ...2016 The Clorox Company Professional Products Division 1221 Broadway Oakland CA 94612 1 800 492 9729 www cloroxtotal360 com NI 35818 Electrostatic Sprayer CLX1000 115VAC 60Hz 7 0 A...

Reviews: