Cloos Arc Flash 4 evo Operating Instructions And Spare Parts List Download Page 7

7

Choking hazard

The user is advised to leave the contaminated area immediately if:

•  The Manufacturer‘s Minimum Design Flow (MMDF) warning Alarm 

sounds.

•  breathing becomes difficult,
•  dizziness or distress occurs,
•  any part of the system becomes damaged,
•  airflow into the Head-Unit decreases or stops,
•  contaminant can be smelt or tasted inside the Head-Unit,
•  Materials that may come into contact with the users skin are not 

known to cause allergie reactions to the majority of individuals but in 
the unlikely event of a reaction, the user should immediately leave the 
contaminated area, remove the unit and seek medical advice.

2.5  Warranty clause

If any of these conditions are not kept or followed, the warranty is automa-
tically invalid.

Nothing is allowed to touch the moving parts.

There is no attempt to modify or alter the unit or filter in any way. No wa-
ter or other Iiquids enter the unit in any way - in particular the motor and 
fan, the filter or the battery.

Make sure that the headpiece fits the user‘s face perfectly. Only then the 
efficiency of the system is sufficient. The protective factor of the complete 
system is reduced if the seal of the headpiece is not fitted properly, for e.g. 
due to beards or long hair intervening into the seal line.

There is a possibility that the hose to the head unit may become caught up 
in use. The blower unit should be positioned on the person in such a way 
as to reduce this possibility. 

Filters cannot be fitted directly to the head units and should not be adap-
ted to do so. Correct respiratory protection will not be provided if any parts 
of the equipment are modified. At very high work rates the pressure in the 
device may become negative at peak inhalation flow. Blower unit systems 
are for use only by competent, trained personnel.

Filters should not be modified to fit different blower units.

WARNING!

Summary of Contents for Arc Flash 4 evo

Page 1: ...Operating instructions and spare parts list Welding accessories CLOOS Arc Flash 4 evo Air Rev 0 Original instructions...

Page 2: ...and telephone number information is printed at the back off this leaflet CLOOS ArcFlash4air has been designed and manufactured to comply with EN12941 1998 as a TH2P R SL device 8S4275 Guide to implem...

Page 3: ...ransportation 9 4 Unpacking Assembly 10 4 1 Unpacking 10 4 2 Assembly 10 4 2 1 Waist Belt Adjustment 10 4 2 2 Particulate Filter 10 4 2 3 Removing the Filter 11 4 2 4 Fitting a new Filter 11 4 2 5 Cha...

Page 4: ...arc welding 1 2 Explanation of symbols Warning and safety instructions in the manual are identified by means of pictograms and highlighted in a colour coded block Warning and safety instructions whic...

Page 5: ...se of untrained and non instructed personnel Unauthorised alterations Technical changes Use of unauthorised spare parts 1 4 Copyright This document is protected by copyright The unauthorised transfer...

Page 6: ...he unit must not be used in an atmosphere that is immediately hazar dous to user hygiene or health and or has oxygen content of less than 17 or contains unknown substances in confined spaces or unvent...

Page 7: ...it or filter in any way No wa ter or other Iiquids enter the unit in any way in particular the motor and fan the filter or the battery Make sure that the headpiece fits the user s face perfectly Only...

Page 8: ...he date of purchase This guarantee is subject to The blower unit has been used solely for the purpose for which it is intended The blower unit has not been subject to misuse accident modification or r...

Page 9: ...an 8 hours 5 hours on maximum flow rate Operating time can be shortened in case of clogged filter under charged battery Filter Symbols R means the filter is reusable for more than one shift S means th...

Page 10: ...e half Repeat the above processes until a comfortable and secure fit is achieved Once the belt fits correctly secure any excess belt material using the velcro sections 4 2 2 Particulate Filter Use onl...

Page 11: ...d stretch the new one into position It s important to ensure that the filter media of the main filter is completely covered by the Pre Filter 4 2 6 Attaching the Hose to the Blower Unit Align the pins...

Page 12: ...l If the indicator is below the minimum flow rate level it is necessary to charge the battery or change the filter If the problem still persists see chapter 8 for additional sugge stions 5 3 Batteries...

Page 13: ...has been completed the trickle charging regime is ac tivated red LED Diode goes out the green LED diode comes on at the moment of trickle charging 5 3 2 Battery changing Removing the battery 1 Locate...

Page 14: ...ower level if it fails to meet the lower level the alarm will still sound When the airflow falls below the minimum safe operating level a second audible alarm joins the first and the unit will vibrate...

Page 15: ...infecting Liquids must not be allowed to enter the workings of the blower unit or get on to the element of the filter Parts should be allowed to air dry Under no circumstances should any solvents or a...

Page 16: ...ly system are assembled properly the battery and its connector whether the charger is not faulty or malfunctioning if so diodes do not work Filters and their clogging That there is not a hole in the a...

Page 17: ...seal 0875006253 Arc Flash 4 air filter complete 0875006254 Arc Flash 4 air hose cover 0875006255 Arc Flash 4 air hose 0875006256 Arc Flash 4 air particle filter 0875006257 Arc Flash 4 air prefilter 1...

Page 18: ...18 List of parts Arc Flash 4 air belt with lumbar support 0875006262 Arc Flash 4 air ventilation grill 0875006263 Arc Flash 4 air storage bag 0875006264...

Page 19: ...19...

Page 20: ...www qineo de Carl Cloos Schwei technik GmbH Industriestra e D 35708 Haiger Germany Telefon 49 0 2773 85 0 Telefax 49 0 2773 85 275 E Mail info cloos de www cloos de...

Reviews: