CLIVET AQUA SWAN 190 Installation And Operating Manual Download Page 36

36  

10 - CONTROL

 

5 - Anti-legionella mode (Disinfect) 

Icon  

 will be lightened when the unit is under disinfect mode, otherwise  

 will be extinguished. 

Icon  

  will be lightened if disinfect mode is automatically activated by unit;  

   will flash with 0.5 sec frequency, if disinfect mode is manually activated;  

will flash with 2 sec. frequency when setting disinfect mode or setting disinfect timer. 

6 - High temperature Alarm 

If setting water temperature is higher than 50°C,   icon 

  will be lightened, otherwise 

 will be extinguished. 

8 - Lock

 

If button is locked, icon  

 will be lightened, otherwise  

  will be extinguished. 

9 - Temperature unit

 

If setting temperature unit as celsius,  

°C

  will be lightened, icon 

  will show celsius degree;  

If setting temperature unit as Fahrenheit, 

°F

  will be lightened, icon  

  will show Fahrenheit degree. 

Press   

   for 10sec, it will change between   

°C

  and  

°F

   

10 - Invalid 

 

If button is under lock mode, press any button except unlock button, this icon  

  will be lightened. 

7 - Alarm

 

When unit is under protection/error, icon  

  will flash with 5 sec. frequency as well as buzzer will sound 3 times every 1 minute until 

protection/error eliminated or press  

  for 1 second. 

11 -  

 

Icon  

will be lightened if screen is unlocked. 

It shows water temperature on normal mode; 

It shows remaining vacation days on vacation mode; 

It shows setting temperature under setting mode; 

It shows unit setting/running parameters, error/protection code under query mode. 

12 -  

 

Reserved

 

Summary of Contents for AQUA SWAN 190

Page 1: ...15 11 2017 AQUA SWAN 190 300 Heat pumps for domentic hot water INSTALLATION AND OPERATING MANUAL M0MR40E17 00...

Page 2: ...pany is to offer advanced systems that assure the best comfort reduce energy consumption and the installation and maintenance cost for the life cycle of the system The purpose of this manual is to pro...

Page 3: ...1 The data contained in this manual is not binding and may be modified by the manufacturer without prior notice preliminary Before any operation carefully read the GENERAL WARNINGS INSTALLER use WARNI...

Page 4: ...e electric cables that come out from the device even if it is disconnected from the mains supply It is forbidden to trample on the device and or to put on it any type of object It is forbidden to thro...

Page 5: ...to things and injuries to people are reported Installation starting maintenance and repair required specific knowledge if they are carried out by inexperienced personnel they may cause damages to thi...

Page 6: ...ctrical installations moreover the lines must be in conformity with regulations in force Operate in compliance with safety regulations in force This unit is required reliable earthing before usage oth...

Page 7: ...Before starting work verify that the sectioning device at the start of the unit power line is open blocked and equipped with sign warning First create the earthing connection After wire connection che...

Page 8: ...ounding the area occur could cause explosions or fires Carefully check the positioning of the unit The installation of the unit in a place unsuited to support its weight and or guarantee adequate anch...

Page 9: ...work in progress with the appropriate shield Contact with parts that could be under voltage due to the start up of the unit may cause electric shocks burns and electrocution When voltage is necessary...

Page 10: ...ng must be recovered if present refrigerant gas When awaiting dismantling and disposal the unit can also be stored outdoors as bad weather and rapid changes in temperature will not cause damage to the...

Page 11: ...logo and address Serial number It identifies uniquely each machine It identifies specific spare parts for the machine Assistance request Note data from the serial number label and write them in the ch...

Page 12: ...let 3 4 F 2 Domestic hot water outlet 3 4 F ACS 3 Sacrificial anode 4 Anode cap 5 Electric heater 6 Heating element cap 7 Front mask 8 Front cover 9 Unit control keypad 10 Fan 11 Top cover 12 Air outl...

Page 13: ...let 3 4 F 2 Domestic hot water outlet 3 4 F ACS 3 Sacrificial anode 4 Anode cap 5 Electric heater 6 Heating element cap 7 Front mask 8 Front cover 9 Unit control keypad 10 Fan 11 Top cover 12 Air outl...

Page 14: ...unit weighs The following examples are indications the choice of the means and of the handling modes will depend on factors Identify critical points during handling disconnected routes flights steps...

Page 15: ...e the unit Keep packing material out of children s reach it may be dan gerous Recycle and dispose of the packaging material in conformity with local regulations 4 3 PACKAGING REMOVING 1 2 3 Front Rear...

Page 16: ...this unit in heat pump mode the external air temperature must be above 7 C and below 43 CIf the externalair temperature falls outside these upper and lower limits the electrical elements will activat...

Page 17: ...15m and must have unrestricted air flow Make sure there is enough Installation space 50mm larger than the diameter of unit Heat pump 5 6 CONDENSATE DRAIN Condensate may be leaked from unit if drainag...

Page 18: ...never be re moved Installation OK 6 1 WATER FEATURES 6 4 PRESSURE REDUCER Provided by the customer 6 3 WATER FILTER Provided by the customer If the inlet water pressure is less than 0 2MPa 2bar a pump...

Page 19: ...should be installed at a horizontal floor Otherwise the drain vent is ensured at the lowest place Recommending the inclination angle of unit to the ground should be no more than 2 Condensate drain lin...

Page 20: ...hot water Do not use flexible pipes for unit connection Indicative plumbing diagram The system components must be defined by Designer and Installer ex expansion tanks vents taps calibration safety val...

Page 21: ...thermostatic 10 Condensate drain 11 Solar circulation unit KCVEX ELFOSun 12 ELFOSun A Aqueduct inlet B DHW C DWH recirculation 190S 300S Indicative plumbing diagram The system components must be defi...

Page 22: ...rating condensate will be generated aroud outside of duct Thermically insulate the supply ducts to avoid heat losses and condensate 7 2 AIR DUCT CONNECTION The dimensioning and the correct execution o...

Page 23: ...put on the position of duct inlet Provided by the customer Air filter A Air filter Unit 190 litres A The air filter must be provided on the intake outlet of the external air or on the duct easily acc...

Page 24: ...vailable pressure head supplied by the unit INTAKE AND EXPULSION DUCTS recommended Installation with an intake duct and free expulsion is recommended if there is a desire to use the air expelled by th...

Page 25: ...orator temperature sensor T4 Ambient temperature sensor T5U Storage tank temperature sensor Upper T5L Storage tank temperature sensor Lower TP Discharge temperature sensor TH Suction temperature senso...

Page 26: ...orator temperature sensor T4 Ambient temperature sensor T5U Storage tank temperature sensor Upper T5L Storage tank temperature sensor Lower TP Discharge temperature sensor TH Suction temperature senso...

Page 27: ...0L model Power frequency 50 60Hz selection CN27 Panel disply power supply S V Saftey valve CN5 High pressure switch CN28 Transformer output CN29 Crankcase heather CN16 Tp compressor discharge temp sen...

Page 28: ...t The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram An all pole disconnection device which has at least 3 mm separation d...

Page 29: ...unit connection make sure that the hydraulic system has been cleaned up and the clearing water has been drained Check that the water circuit has been charged and pressurised Check that the cut off val...

Page 30: ...ition excessive dust and lint may affect the operation of the unit and require more frequent cleaning 8 The externalair temperature must be above 7 C and below 43 C If the externalair temperature fall...

Page 31: ...f leaks 13 Hydraulic system filled pressurised and drained 14 Expansion tank checked filled with nitrogen 15 Condensate and safety valve drains 16 Condensate drain line installation Must be located wi...

Page 32: ...2 Correct installation of the system 3 Correct connection of water air piping and wiring 4 Condensate draining smoothly well insulation work for all hydraulic part 5 Correct power supply 6 No air in t...

Page 33: ...ror code E7 and will be shown on the display then heat pump will stop running and the unit will activate automatically E heater as the backup heat source but the code E7 and will be shown until power...

Page 34: ...perature Query function For the convenience of maintenance and debug query function is available by press 2 buttons together then system running parameters will be shown one by one with following sequ...

Page 35: ...ed if the unit is under vacation mode will flash with 2 sec frequency when setting vacation mode otherwise will be extinguished 3 Compressor Icon will be lightened when compressor is running otherwise...

Page 36: ...f setting temperature unit as celsius C will be lightened icon will show celsius degree If setting temperature unit as Fahrenheit F will be lightened icon will show Fahrenheit degree Press for 10sec i...

Page 37: ...extinguished If timer is being set icon will flash the corresponding one with 2 sec frequency as well lighten the timer which has been set Press E HEATER Icon will flash Press For confirm manually tu...

Page 38: ...ur value of clock Press For confirm the hour setting Then the minute value of clock will flash slowly Set the minute value of clock Press For confirm the minute setting and quit clock setting 3 Set Cl...

Page 39: ...t been set when press button CANCEL the display will show After complete cancelling timer press button CANCEL for 3sec to quit timer cancelling Press Enter timer checking Check Timer Scheduling Select...

Page 40: ...mer value will be decreased continuously When setting vacation days press more than 1sec day value will be decreased continuously Under query mode check items will page down by pressing If screen and...

Page 41: ...fault as 14 days Confirm vacation setting and quit out The unit will immediately go into vacation mode In vacation mode the setting target water temperature is 15 C as default will show the remanent v...

Page 42: ...he system will be stopped and start self check and restart when the protection resolved When the self protection happens the buzzer will buzz in every other minute the will flash and error code will b...

Page 43: ...he unit E6 Compressor discharge temperature sensor TP error Maybe the connection between sensor and PCB has released or sensor has been broken Contact a qualified person to service the unit E8 Electri...

Page 44: ...PCB and compressor P4 Compressor overloaded protection 10 sec after compressor startup Current checking starts 1 only compressor running if it is 10A the compressor will be stopped and protected 2 Com...

Page 45: ...re is still a mount of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 storage tank when tapping hot water out it means there is at least 1 4 storage tank of hot w...

Page 46: ...Replace it if it has been used out 3 Inner storage tank Every half year Clean the storage tank 4 Electric heater Every half year Clean the resistance 5 Saftey valve Every year Turn the knob If water...

Page 47: ...the water freezing and damage of E heater If a long period of inactivity is foreseen put the unit in OFF wait a few minutes to allow all the actuators to reach the rest position Turn off the power in...

Page 48: ...its diameter is of a third of the original anode Remove power supply Turn off the water inlet valve A Open hot water tap for decrease the pressure of the storage tank Open tap B Empty the storage up...

Page 49: ...ean it completely finally remount it to the unit 11 12 RESTART AFTER A LONG TERM STOP When the unit is restarted after a long term stop included trail running it is normal that outlet water is unclean...

Page 50: ...e and make sure effective sealed Check that there are no water losses from the fitting Restore the electric connections Put the cover cap B and fix Put de frontal cover A Open the water inlet tap C un...

Page 51: ...0 680 Shipping width mm 680 680 1 Compressor compartment 6 Functional spaces 11 Solar outlet 3 4 F only 190S 2 Electric panel 7 Magnesium anode 12 Domestic hot water recirculation only 190S 3 Unit key...

Page 52: ...5 775 Shipping width mm 745 745 1 Compressor compartment 6 Functional spaces 11 Solar outlet 3 4 F only 300S 2 Electric panel 7 Magnesium anode 12 Domestic hot water recirculation only 300S 3 Unit key...

Page 53: ...890 1341 Daily consumption kWh 4 22 6 26 4 22 6 26 COP EN 16147 2 76 3 04 2 76 3 04 Clima Warmer Heat pumps Water Heater 5 Domestic hot water profile L XL L XL wh 125 143 125 143 Annual consumption AE...

Page 54: ...The product complies with the European Directive ErP which includes the Commission Delegated Regulation EU N 812 2013 and the Commission Delegated Regulation N 814 2013 Colder Climate Heat Pump Water...

Page 55: ...55...

Page 56: ...celona Espa a Tel 34 93 8606248 Fax 34 93 8855392 info clivet es Av Manoteras N 38 Oficina C303 28050 Madrid Espa a Tel 34 91 6658280 Fax 34 91 6657806 info clivet es CLIVET GmbH Hydronic and Applied...

Reviews: