DVR - 

Manual Record  / Schedule Record

Schedule Setup: 

•  Schedule: 

Turn Schedule Recording On/Off. The Schedule map is laid out in hours of the day. Each hour can have 

a different type of recording mode set to it. Navigate between the hours using the UP or DOWN button on the 

remote. Press the LEFT or RIGHT button to change the recording type; Alarm, Motion, Continuous (Calendar), 

All Modes, or No modes.

MANUAL RECORD

The DVR has multiple recording modes; Manual, Schedule, Event & Continuous. Each recording mode has 

individual options for recording quality.

Manual Recording occurs when the REC button on the remote is pressed. To stop Manual recording press the 

EXIT button.

SCHEDULE RECORD

Adjust the different settings of Schedule, Event/Motion & Continuous Recording modes.

SCHEDULE RECORD

    1920x1080        25 FPS

    1920x1080        25 FPS

    1920x1080        25 FPS

SCHEDULE SETUP      >

EVENT     RECORD      >

CONTINUE RECORD   >

ALARM

MOTION

CONTINUOUS - CALENDAR

ALL

NONE

MANUAL RECORD

VIDEO SIZE            : 1920x1080        

FRAME RATE         : 25 FPS

QUALITY             : HIGH

Recording Modes

Summary of Contents for CE-RP5

Page 1: ...R ON DEVICE the r PC Attach the main power cord to the PVM Turn the CE RP5 power switch to the ON position The Record and Power lights on the front of the CE RP5 will illuminate 8 VIEW MENU AND FILES REC EXIT PLAY MENU ENTER 6 LED 5 LED 4 GND 3 MOTION OUT 2 GND 1 ALARM IN REC PWR H 264 FULL HD SDI RECORDER with converter ...

Page 2: ...E OVERVIEW 1 HD SDI Output 2 HDMI monitor output 3 Analog Output 4 DC12 Volt Power Input 5 OSD Menu Navigation Buttons Up Right Down 6 LED Output Connect a single LED diode to LED LED which will illuminate in conjunction with the main recording LED on the front of the device 7 Event Alarm Output Connect 4 GND Motion Out This is a normally closed alarm output which will become open when triggered b...

Page 3: ...within the OSD menu 2 Menu Enter Press to enter OSD menu and for OSD selection 3 Play Pause Press once to enter playback mode Press again when in playback mode to pause 4 Record Press to start manual recording 5 Exit Press to stop manual recording or to exit a current menu selection 6 OSD ON OFF Press to hide or show the menu information date time resolution etc RemoteControl ...

Page 4: ...UT 2 GND 1 ALARM IN REC PWR H 264 FULL HD SDI RECORDER with converter 64 REC EXIT PLAY ME NU EXIT REC PW R H 264 FULL HD SDI RECO RD ER with converter 6 LED 5 LED 4 GN D 3 MO TIO N OU T 2 GN D 1 ALARM IN OFF ON DC12V IN HD SDI IN VIDEO OUTPUT BasicSetup BASIC SETUP 1 Connect barrel plug from DC12 Volt 1 Amp Power supply to device Power supply sold separately 2 Plug outlet from DC12 Volt Power Supp...

Page 5: ...acts facing down as shown below 6 Turn the Power switch on the side of the device to ON Power and record LEDs should illuminate green BasicSetup This device is factory set to record on motion events only To record on alarm calendar or schedule make changes in the Schedule Record menu NOTICE Maximum SD Card size is 128GB NOTICE v 05 04 clintonelectronics 6701 Clinton Road Loves Park IL 61111 800 54...

Page 6: ...ate will not effect this input resolution frame rate nor will it effect the device s output resolution frame rate MenuIconsExplained LiveView DVR Menu Navigation Press MENU ENTER to open the OSD menu Press UP or DOWN on the remote control to navigate To confirm or make a selection press the MENU ENTER button Press the LEFT or RIGHT buttons to change the value Press the EXIT button to go back to th...

Page 7: ... 2 Playback Mode Play Pause Fast Forward Rewind Slow Playback 3 Playback Speed 4 Record Mode 5 Recorded Video Resolution 1920x1080 1280x720 6 Recorded Video Quality Basic Quality Normal Quality High Quality 7 Timestamp Watermark Alarm input Motion Calendar Manual Pre Record 05 30 2018 10 53 44 05 30 2018 10 53 44 1920 1080 2x 3 4 5 6 7 ...

Page 8: ...desired recording as it is only the last few seconds before the SD Card was pulled AVI video files are not viewable on Apple MAC computers Normal Playback Speed Fast Forward Fast Rewind During normal playback press Fast Forward or Fast Rewind button in the same direction again to increase the search speed Speed x2 x4 x8 x16 x32 Press Play Pause button to playback at normal speed Pause Slow Playbac...

Page 9: ...tion detection cell To change the Mode of selection press the REC button Cell Edit Turn On Off cells individually DEL Block Turn Off large blocks of cells DEL All Turn all cells Off Add Block Turn On large blocks of cells Add All Turn all cells On Set MD Sensitivity MD Energy Displays current recognized motion Motion is displayed as RED blocks MD Threshold Press Left or Right on the remote control...

Page 10: ...es or No modes MANUAL RECORD The DVR has multiple recording modes Manual Schedule Event Continuous Each recording mode has individual options for recording quality Manual Recording occurs when the REC button on the remote is pressed To stop Manual recording press the EXIT button SCHEDULE RECORD Adjust the different settings of Schedule Event Motion Continuous Recording modes SCHEDULE RECORD 1920x1...

Page 11: ...s the total available remaining space on the SD Card Max File Size Set the file size limit for recorded video files Once the limit is reached a new file will start to record Card Full Choose between LOOP or STOP LOOP Oldest files will be overwritten when the card is full STOP When the card is full recording will stop Format Formats the SD Card to FAT32 All information saved on the SD Card will be ...

Page 12: ...at and alarm input type as needed NOTE If connecting to a DVR it may be necessary to change the TV Output to 1080p30 FACTORY DEFAULT Reset all DVR settings to factory default Date time information will not be reset SYSTEM STATUS VERSION V2 0101 SD FULL LOOP 1920x1080 25FPS 1920x1080 25FPS 1920x1080 25FPS 1920x1080 25FPS POWER ON SETUP LANGUAGE ENGLISH TV OUTPUT 1080I60 PASSWORD 0 0 0 0 ALARM INPUT...

Page 13: ...his manual Clinton reserves the right without notification to make changes in product design specification ver 06 06 18 Clinton Electronics 6701 Clinton Road Loves Park IL 61111 Technical Support 1 800 549 6393 Monday Friday 8am 5pm Central Standard Time www clintonelectronics com CE RP5 UserManual ...

Reviews: