84
EN
– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
NOTE:
holding the buttons
>
or
<
increases the speed of the scrol-
ling movement.
– once the required parameter has been reached, press the but-
ton
o
for approximately 3 seconds to confirm and access the
set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
<
to decrease it
– once the required value has been reached, press the button
o
to confirm.
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
<
and
o
at the same time
for approximately 5 seconds until the initial
screen is displayed.
7.4
List of parameters
Type
No.
Description
Range
U/M
Step
Default
CONFIGURATION
tS
0.1
Index showing boiler power in kW
0 = 24
1 = 28
2 =40
-
1
0 or 1 or 2
tS
0.2
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or
heating only
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
-
1
0
tS
0.3
Gas Type Configuration
0 = G20
1 = G31
-
1
0 or 1
tS
0.4
Combustion configuration
0 = sealed chamber with combustion
control
1 = open chamber with smoke thermostat
2 = low NOx
-
1
0 or 1
tS
0.8
External sensor value correction
-5 .. +5
°C
1
0
DOMESTIC HOT WATER - HEATING
tS
1.0
Boiler Antifreeze Threshold
0 .. +10
°C
1
3
tS
1.1
External Sensor Antifreeze Threshold
-- = Disabled
-9 .. +5
°C
1
-2
tS
1.2
Heating Curve Incline
0 .. 80
-
1
20
tS
1.3
Minimum Heating Temperature Adjustment
20 .. Par tS 1.4
°C
1
20
tS
1.4
Maximum Heating Temperature Adjustment
Par tS 1.3 .. 80
°C
1
80
tS
1.5
Maximum power heating
0 .. 100
%
1
100
tS
1.6
Heating Post-Circulation Time
0 .. 99
seconds
x 10
1
3
tS
1.7
Heating Pump Activation Delay
0 .. 60
seconds
x 10
1
0
tS
1.8
Re-ignition Delay
0 .. 60
Min
1
3
tS
1.9
Domestic Hot Water Modulation with Flow meter
0 = Disabled
1 = Enabled
-
1
1
tS
2.0
Maximum power domestic hot water
0 .. 100
%
1
100
tS
2.1
Minimum power heating/domestic hot water (pre-
mixed)
0 .. 100
%
1
0
tS
2.2
Domestic hot water preheating enabling
0 = OFF
1 = ON
-
1
0
tS
2.5
Internal parameter (no change)
-
-
-
0
tS
2.6
Zone Valve / Pump Relaunch Delay
0 .. 99
Min
1
1
tS
2.9
Anti-legionella Function (Only hot water tank)
-- = Disabled
50 .. 80
-
1
--
tS
3.0
Maximum domestic hot water temperature
35 .. 67
°C
1
60
Summary of Contents for 24 BF
Page 10: ...10 FR ...
Page 49: ...49 FR ...
Page 58: ...58 EN ...
Page 97: ...97 EN ...
Page 98: ...98 ...
Page 99: ...99 ...
Page 100: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Page 101: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Page 102: ...51 ...
Page 103: ...50 ...
Page 104: ...49 ...
Page 143: ...10 ...