Features
Battery and Low Battery Detection
The Thermostat uses 2 AA Alkaline batteries as its power source. The Thermostat features Low Battery Detection
function. When the battery voltage is low, the Thermostat will transmit Low Battery signal to the coordinator in ZigBee
network.
Relay Control
The Thermostat control home heating/cooling system through relay control. Open and flip over the back cover,
remove the internal cover on the relay to reveal the terminals for wiring. When wiring the Thermostat, wire the cable
through the central opening on the back cover.
Mode Control
The Thermostat has two operation modes: Local mode and Scheduled mode.
Local Mode:
Local mode allows adjustment of Thermostat Heat/Cool function and setpoints using thermostat buttons.
Scheduled Mode:
Scheduled mode allows Thermostat mode and setpoint control via Gateway after learning is completed.
To change the operation mode, please refer to
“
Programming Mode
” section for more details.
Heating/Cooling and Setpoint Control
The Thermostat Heating/Cooling and setpoint can only be adjusted locally when Thermostat is set to Local mode.
When under local mode, press the
UP
(
+
) or
Down (-)
button to adjust setpoiont.
When under scheduled mode, use the Gateway/Control Panel to adjust the setpoint remotely.
Heat setpoint range: 9
°
C ~ 30
°
C.
Cool setpoint range: 11
°
C ~ 32
°
C
Remote Control
After the Thermostat joins a ZigBee network, you can control the Thermostat via ZigBee network coordinator or
gateway. Please refer to your ZigBee coordinator/gateway manual for more information.
The following functions are only available for setting via ZigBee coordinator and gateway:
Schedule:
You can only program Schedule configuration via ZigBee network coordinator/gateway.
Schedule Setting: Up to 5 schedules can be programmed for every weekday with Mode, Setpoint and Start time.
Schedule Control:
Normal - The Thermostat will execute programmed schedule setting accordingly.
Hold
– The Thermostat will bypass currently timed schedule and perform the next schedule when it begins
No Schedule
– The Thermostat will not execute any set schedule until it is set to Normal again.
Temperature Detection
The Thermostat has built-in temperature sensors and will display the temperature reading on the LCD display.
The Thermostat will transmit temperature signals regularly according to setting. The factory default interval is 10
minutes.
When the temperature changes by +/- 2
°
C, the Thermostat will also transmit a signal.
You can also press the ZigBee Network Button once to transmit a temperature signal manually.
Supervision
The Thermostat will transmit a supervision signal every 10 minutes along with the temperature, current mode and set
point information to report its condition regularly.