Page 14
FF3000 Operating Manual
Power connection
WARNING
To prevent serious injury from moving machinery during
setup or adjustment, use quick disconnects provided
between the air supply line and the ball valve. Close
and lock out air valve before connecting the air supply
line to the motor.
The air filter and lubricator supplied with the machine must be
used or the warranty is void. The lubricator should be set to
deliver oil at a rate of 15-20 drops per minute.
CAUTION
To prevent damage to the machine, use the filter and
lubricator provided.
1. Close and lock out the air valve.
2. Connect the air supply to the pneumatic conditioning unit. Be
sure the air supply line is at least 3/8".
3. Make sure the ball valve is turned off. The ball valve is closed
when the handle is perpendicular with the air line.
4. Connect the air supply line from the pneumatic conditioning
unit to the machine using quick disconnect fittings.