Features 

 

Battery and Low Battery Detection 

  The SDCO-1 uses three EL123AP Lithium Batteries as its power source. The batteries are included in the package.   
  The SDCO has a foolproof mechanism which prohibits cover closure without first installing battery. 
  When the SDCO is low on battery, a low battery signal will be transmitted along with regular signal transmissions. The Amber LED 

will flash with a low-volume beep once every 45 seconds. 

  Both Red and Amber LED will flash once every 4 seconds when batteries are extremely low and needed to be replaced.   
  When changing the batteries, after removing the old batteries, press the Test Button twice to fully discharge before inserting new 

batteries. 

 

Getting Started 

 

Step 1:

 Use a Phillips screwdriver to loosen the battery compartment fixing screw, and remove the battery compartment cover. 

 

Step 2:

 Insert 3 batteries into the battery compartment. 

 

Step 3: 

The SDCO Detector will emit 2 short beeps, and begin warm up process for 

1

 minute. LED will flash every 2 seconds. 

Step 4.

  During the 1 minute period, learn in the Smoke Detector.   

a.   Press the Learn/Test button once to transmit an IR sensor learn code.   
b.   Press and hold the Learn/Test button for 3 seconds to transmit a Smoke/Temperature sensor learn code 

(step a. and step 

b. are both required for serial connected models)

If the Control Panel receives the signal, the Smoke Detector will emit a 2-tone beep. Refer to Control Panel manual to 
complete learning process. 

 

Step 5: 

When 1-minute warm up period expires, the SDCO Detector will emit a beep to indicate it now enters calibration process. The   

 

 

  calibration process takes 1~7 minutes; the LED will continue to flash during calibration.   

 

Step 6: 

When calibration is complete, the SDCO Detector will emit a 2-tone sound and LED will stop flashing to indicate it is now under   

normal operation. If calibration fails, the SDCO Detector will sound continuous beeps. 

 

 

Alarm Detection 

 

The SDCO Detector will activate fire alarm when either of its smoke detection or high heat detection function is triggered. When an 
alarm is activated, the SDCO Detector will transmit alarm signal and raise alarm with its built-in buzzer. The Red LED will flash rapidly.   

Smoke Detection: 

  The SDCO Detector checks smoke concentration every 8 seconds 
  Whenever  the  smoke  concentration  exceeds  the  detection  threshold,  SDCO  will  send  active  signal  to  the  Control  Panel,  and 

activate the alarm. 

  If  the smoke concentration  persists,  the SDCO  Detector  will continue  to send the  active signal  every 2 minutes to the  Control 

Panel. 

  If no smoke is detected for 20 continuous detection times, the SDCO will transmit a restore signal and stop the alarm. 

Heat Detection (For SDCO-1H-F1 and SDCO-1H-F1-2W models only): 

  The SDCO Detector checks temperature every 10 seconds. 
  The alarm will be activated in the following conditions: 

- When the temperature rises by 8.25°C per minute (Rate of Rise). 
- When the temperature exceeds 57.25°C (High Heat). 

  If no high heat is detected for 20 continuous detection times, the SDCO will transmit a restore signal and stop alarming. 
  If  the  alarm  was  triggered  by  High  Heat  condition  (57.25°C),  the  temperature  must  drop  below  49°C  for  the  Detector  to  stop 

alarming.   

  If the alarm was triggered by Rate of Rise condition (8.25°C per minute or more), the temperature must drop to 4°C below highest 

temperature detected for the Detector to stop alarming.   

Carbon Monoxide Detection: 

  The CO sensor checks the CO concentration level every 16 seconds. If the concentration level exceeds the detection threshold, 

the SDCO Detector will transmit alarm signal and raise alarm with its built in buzzer.   

  The CO sensor features self-diagnosis function and will regularly check the health or status of the sensor every 12 hours.     
  The  alarm  will  be  activated  after  CO  concentration  is  detected  according  to  time  length  in  the  following  table:  (compliant  with 

EN-50291 standard) 

CO concentration level 

Time taken before alarming 

30 +/- 10% ppm 

N/A 

50 +/- 10% ppm 

60~90 minutes

 

100 +/- 10% ppm 

10~40 minutes

 

300 +/- 10% ppm 

Under 3 minutes

 

  The  alarm  will  be  activated  after  CO  concentration  is  detected  according  to  time  length  in  the  following  table:  (compliant  with 

UL-2034 standard) 

CO concentration level 

Time taken before alarming 

30 +/- 3% ppm 

N/A 

70 +/- 5% ppm 

N/A

 

70 +/- 5% ppm 

60~240 minutes

 

150 +/- 5% ppm 

10~50 minutes

 

400 +/- 10% ppm 

4~15 minutes

 

  Once the CO concentration level exceeds the threshold and persists for the time length as listed in the above table, the SDCO 

Detector will transmit the signal to the Control Panel and raise alarm with its built-in siren. 

 

Testing the SDCO Detector 

By pressing the Test Button on the SDCO Detector, you can test if the SDCO is functioning normally. 

  If the SDCO Detector functions normally, the Red LED will flash once followed by a 2-tone beep. 
  If three 2-tone beeps (DO-DI DO-DI DO-DI) are emitted, it means the Smoke Sensor is out-of-order. 