<NOTE>
After setting the sensitivity level from the Control Panel, please press and hold the button on the fall sensor for 8
seconds to receive the sensitivity level data from the Control Panel. The LED (green under normal mode; red
under low battery status) will light up upon receiving data from the Control Panel. Please press the active button
on the fall sensor again for more than 2 seconds to notify the Control Panel and confirm the sensitivity level
update.
F. Inactivity Detection
If a fall is detected, the sensor will transmit an alarm signal to Control Panel. If no sudden movement was detected within 10
seconds after fall detection, the Fall Sensor will transmit another inactivity code to Control Panel
G. Usage Recommendation
Best way to wear a fall sensor
(O)
A. Let it hang in front of the chest and adjust necklace length so that the sensor hangs at the bottom of the sternum
as shown in the picture below.
B. Wear the pendant exposed outside and in front of any clothes or heavy/feather jacket.
C. When a fall occurs, it is best if the fall sensor can touch the ground.
Wrong way to wear a fall sensor
(X)
A. Necklace being too short (around clavicle) or too long (below sternum) is likely to cause false trigger or no
response.
B. Fall sensor being worn inside a chest pocket will lead to non-detected condition.
Carefully place the fall sensor on a desk when you are not using it in order to avoid triggering a false alarm.
Due to the nature of fall detection mechanism, fall detection cannot be 100% accurate. False alarm or detection
failure during daily use could not be avoided completely. Please utilize the Active Button to activate alarm manually
when needed to ensure safety.
H. Sleep Mode
If the fall sensor remains stationary for more than 3 hours, it will enter Sleep Mode. If movement is detected during
sleep mode, the fall sensor will start a 1-minute countdown to return to normal operation mode. Fall detection
function is disabled during the 1-minute timer, and the user is allowed to put on the Fall Sensor without activating
false alarm. When the 1-minute timer expires, the Fall Sensor will return to normal operation.
I. Testing
During testing, do not trigger the fall sensor twice within a 10-second interval.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Caution:
To assure continued compliance, any changes or modifications not expressly approved by the party responsible for
compliance may void the user's authority to operate this equipment. (Example - use only shielded interface cables when
connecting to computer or peripheral devices).
2